MAINTENANCE INSTRUCTIONS

Condensing water

During the heating season, humidity of extract air condenses into
condensing water. Water formation may be abundant in new
buildings or if ventilation is low compared to the humidity build-up
caused by the residents.
Condensing water needs to fl ow out from the ventilation unit without
hindrance. In carrying out maintenance, for instance in autumn
before the beginning of the heating season, make sure that the
condensing water outlet (L) in the bottom tank is not clogged. You
can check it by pouring a little water in the tank. Clean if needed.
Do not let water fl ow into electrical devices. The unit comes with
a condensing outlet (in the fi gure) equipped with an airlock and
an outlet without airlock that takes less space. If you use the outlet
without airlock, you have to mount an airlock somewhere between
the discharge pipes (the accessory bag contains the parts needed).
An airlock guarantees the removal of condensing water and
silencing of any sounds.
© VALLOX • We reserve the right to make changes without prior notice.
What the units include can vary depending on the sales area.
Location of condensing water
outlet from side
Vallox TSK
Multi 50
80
Location of condensing water outlet
from behind
MC
MC
MC
5