2 Delivery and handling

Transport

VVM 320 should be transported and stored vertically
in a dry place. However, the VVM 320 may be carefully
laid on its back when being moved into a building.

Assembly

Position VVM 320 on a solid foundation that tolerates
water and the weight of the heat pump. Use the
product's adjustable feet to obtain a horizontal and
stable set-up.
30 - 50 mm
Because water comes from VVM 320, the area where
the heating pump is located must be equipped with
floor drainage.
Installation area
Leave a free space of 800 mm in front of the product.
All service on VVM 320 can be carried out from the
front.
800
NOTE
Leave 10 – 25 mm free space between the in-
door module and the wall behind for routing
of cables and pipes.
NIBE™ VVM 320

Supplied components

Outside sensor
Current sensor*
*Only to 3X400V
Location
The kit of supplied items is placed on top of the
product.