2 Delivery and handling

Transport

The exhaust air module should be transported and stored
in the dry.

Assembly

NIBE FLM is installed on top of the ground heat pump
or freestanding on brackets. Noise from the circulation
pump or fan can be transferred to the brackets.
• Install with its back to an outside wall, ideally in a room
where noise does not matter, in order to eliminate
noise problems. If this is not possible, avoid placing
it against a wall behind a bedroom or other room
where noise may be a problem.
• Wherever the unit is located, walls to sound sensitive
rooms should be fitted with sound insulation.
• Route pipes so they are not fixed to an internal wall
that backs on to a bedroom or living room.
6
Chapter 2 | Delivery and handling
INSTALLATION AREA
Leave a free space of 800 mm in front of the product.
Leave free space between NIBE FLM and wall/fit-
tings/cables/pipes etc. It is recommended that a space
of at least 10 mm is left to reduce the risk of noise and
of any vibrations being propagated.
NOTE
Ensure that there is sufficient space (300 mm)
above NIBE FLM for installing ventilation
hoses.