Technical Data; General Information - Elster enCore FC1 Operating Instructions Manual

Flow computer
Hide thumbs Also See for enCore FC1:
Table of Contents

Advertisement

9 Technical Data

9.1 General Information

dimensions/
housing
ambient conditions
IP protection class
storage temperature
weight
power supply
display/operation
panel
enCore FC1
plug-in unit in 19" technology, 3 height units
(3HU), 1/3 or 1/2 overall width
depth without plug approx. 170 mm, with plugs
approx. 220 mm
process interfacing at the rear, operation
panel at the front
ambient temperature range −10 °C up to
+55 °C
humidity < 90 %, non-condensing
installation outside Ex zones 0, 1 and 2 only
IP20
−25 °C to +60 °C
(fully equipped)
1/3 device width:
1/2 device width:
24 V DC +/− 20 %, power consumption up to
12 W (typically 5 W)
optional: 230 V AC via external power supply
4.3" TFT color display with touch screen,
480×272 pixels RGB, LED background
lighting
4 navigation and 2 function keys
2 multicolor LEDs for power and status
indication
sealable security switch
Table 7: General technical data
Operating Instructions
approx. 1.3 kg
approx. 2.1 kg
Page 91 of 97