Appendix B: Technical Data; General Data (Mechanical); Power Supply; Pulse / Signal Inputs - Elster TC210 Operating Manual And Installation Instructions

Temperature-volume corrector
Table of Contents

Advertisement

Appendix B: Technical data

B-1 General data (mechanical)
Housing/construction
Dimensions (W x H x T)
Weight
Cable connection
Screening
Protection
Ambient temperature
Mounting
Climatic conditions
B-2 Power supply
Device battery
The min. service life of eight years is guaranteed for the following standard operating
mode:
Measurement cycle
Operating cycle
Mode Input 1
Display active
Interface active
Ambient temperature
B-3 Pulse / signal inputs
Two digital inputs with common ground (negative pole) for reed contacts, transistor
switches.
Each input can be parameterised and sealed separately.
Designation
Nominal data
F
When connecting the TC210 in Ex Zone 1, the limits quoted in the certificate of
conformance must also be followed (see Chap. A-2 ).
ELSTER HANDEL GmbH
Plastic housing,
With cable glands
Approx. 157 x 117 x 57 mm
Approx. 600 g
Screw terminals; 0.14 ... 1.5 mm² (solid wire);
use core ferrules for flexible cable.
Connect cable screen to the cable gland.
IP 65
-30 °C ... +60 °C
Using corrosion-protected screws where possible
Suitable for outside installation
Lithium battery module, 3.6V,
16.5 Ah; Order no.: 73015774,
13.0 Ah usable
20 s
300 s (5 minutes)
1 (pulse input)
1 hour per month
15 minutes per month
T
= -10...+50 °C
A
DE1, DE2
TemperatureVolume Corrector TC210