Gas Meter (Turbine): Encoder Index, 2 Lf/Hf Sensors (Eex I) Via Exmfe5 Boards - Elster enCore FC1 Operating Instructions Manual

Flow computer
Hide thumbs Also See for enCore FC1:
Table of Contents

Advertisement

Assembly Instructions
5.4.13 Gas Meter (Turbine): Encoder Index, 2 LF/HF Sensors
(EEx i) via ExMFE5 Boards
Hazardous Area
1234567,8
Turbine:
encoder and
2 LF/HF sensors
encoder index, 2 LF/HF sensors (EEx i) via ExMFE5
Characteristics:
three intrinsically safe, galvanically isolated input safe circuits of the
category [Ex ib Gb] II C for HF- or LF pulse sensor according to
NAMUR;
active isolated pulse amplifier integrated in the inputs as
"associated electrical equipment" according to EN50020
alternatively, one encoder index can be connected with NAMUR
interface on channel 1.
maximum input frequency depending on the operating mode:
LF:
HF:
Page 64 of 97
Safe Area
Fig. 5-18: Interface for turbine meter
Operating Instructions
enCore device
ExMFE5 board
Z1+
Z1−
Z2+
Z2−
Z3+
Z3−
SH
8 Hz with low-pass filter
5 kHz
enCore FC1
5

Advertisement

Table of Contents
loading

Table of Contents