Checking the usage
Electronic index for diaphragm gas meters
BK..ETB (DSMR)
Electronic index for reading out absolute meter read-
ings at base conditions and the valve position. The
index is only suitable for operation in conjunction with
a diaphragm gas meter BK... as a basis.
The meter must only be operated with an inlet pres-
sure the average of which over time corresponds to
the assumed pressure p
cal data).
The national statutory regulations must be observed.
This function is only guaranteed when used within the
specified limits – see page 5 (Technical data). Any
other use is considered as non-compliant.
▷ If the temperature extends outside the limits of
the temperature range, a warning is displayed
and an entry is generated in the error memory. In
addition, the electronic temperature conversion
will be switched off for the duration of the fault.
▷ If the flow rate range is exceeded by more than
20%, a warning is displayed and an entry is gen-
erated in the error memory.
Type code
Code
BK-G
.6
.5
4
6
0
6
5
E
T
Mechanical temperature conversion
B
Part designations
5
Gas meter with electronic index
Display
Selection key
4
Opto-adapter interface
5
Service cap
6
Service seal/screw locking cap
, see page 5 (Techni-
a
Description
Diaphragm gas meter
Flow rate
0.016 – 2.5 m
0.025 – 4 m
0.04 – 6 m
0.06 – 10 m
0.1 – 16 m
0.16 – 25 m
0.25 – 40 m
Electronic index
Volume at base conditions
1
2
5 6 7 8
B K -G x
1 2 3 4
1
-PT B00
-MI 002
DE -07
3
Q
max
Q
min
M0 7 01
02
632 734
002 545
4
6
7
7
Battery
8
Communications module (optional)
Type label/Index plate
Q
max
Q
min
M12 0102
002545632734
Installation
Installing the gas meter
▷ For installing the gas meter in the pipework, refer
to the operating instructions for diaphragm gas
meters BK-G1.6 to BK-G25 → http://docuthek.
kromschroeder.com/doclib/main.php?language=1
&folderid=400041&by_class=2&by_lang=-1.
Gas meter with integrated valve
▷ If the integrated shut-off valve in the gas
meter is closed, it must be released, see
page 4 (Releasing the valve).
Operating the electronic index
▷ The display on the index is switched off.
• Briefly press the selection key.
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
▷ A beep sounds and the main screen appears.
3
/h
▷ An internal buzzer gives audible feedback, e.g. a
short beep indicates a valve is open and a long
beep indicates a valve is closed. A short beep
sounds each time a key is pressed or if the unit
automatically changes back to the main screen.
▷ This function can be switched off.
Main screen
B K -G x
1 2 3 4
1
*
-PT B00
-MI 002
DE -07
Cumulative volume (Vb)
00000.
Q
max
Q
min
M0 7 01
02
632 734
002 545
Menu area
8
Information area
Status line (symbols)
ON
▷ The
OFF
/
a valve is integrated in the gas meter.
GB-2
BK-G..E..
12345678
DE-07-MI002-PTB001
class 1,5
5 6 7 8
m
004
ON
symbols are only displayed when
1
3
2
3