Ice Thickness Check - Manitowoc QuietQube Series Technician's Handbook

Table of Contents

Advertisement

CE THCKNESS CHECK
The ice thickness probe is factory-set to maintain the ice
bridge thickness at 1/8 in. (3 mm).
NOTE: Make sure the water curtain/splash shields are in
place when performing this check. It prevents water from
splashing out of the water trough. Remove the curtain to
make an adjustment, then replace immediately after the
adjustment is made.
1. Inspect the bridge connecting the cubes. It should be
about 1/8 in. (3 mm) thick.
2. If adjustment is necessary, turn the ice thickness
probe adjustment screw clockwise to increase bridge
thickness or counterclockwise to decrease bridge
thickness. Set a 9/32" gap between the ice thickness
probe and evaporator as a starting point. Then adjust
to achieve 1/8" ice thickness.
3. Make sure the ice thickness probe wire and the
bracket do not restrict movement of the probe.
CE BRDGE THCKNESS
PLACE 9/32" (7MM) DRLL BT
HERE TO SET NTAL GAP
NOTE: Turning the adjustment 1/3 of a turn will change the
ice thickness about 1/16" (1.5 mm). Make adjustment only
when the ice machine is off to prevent initiating a harvest.
58
1/8" (3 II)
ce Thickness Check
Part Number: 000015431 Rev01 5/19