Ice Thickness Probe (Harvest Initiation); How The Probe Works; Harvest/Safety Limit Light; Freeze Time Lock-In Feature - Manitowoc P Series Installation, Use And Care, And Service Manual

Point of use ice machine
Table of Contents

Advertisement

Service

Ice Thickness Probe (Harvest Initiation)

HOW THE PROBE WORKS

Manitowoc's electronic sensing circuit does not
rely on refrigerant pressure, evaporator
temperature, water levels or timers to produce
consistent ice formation.
As ice forms on the evaporator, water (not ice)
contacts the ice thickness probe. After the water
completes this circuit across the probe
continuously for 6-10 seconds, a harvest cycle is
initiated.
Ice Thickness Probe

HARVEST/SAFETY LIMIT LIGHT

This light's primary function is to be on as water
contacts the ice thickness probe during the freeze
cycle, and remain on throughout the entire harvest
cycle. The light will flicker as water splashes on
the probes.
The light's secondary function is to continuously
flash when the ice machine is shut off on a safety
limit, and to indicate which safety limit shut off
the ice machine.

FREEZE TIME LOCK-IN FEATURE

The ice machine control system incorporates a
freeze time lock-in feature. This prevents the ice
machine from short cycling in and out of harvest.
The control board locks the ice machine in the
freeze cycle for six minutes. If water contacts the
ice thickness probe during these six minutes, the
harvest light will come on (to indicate that water is
in contact with the probe), but the ice machine will
stay in the freeze cycle. After the six minutes are
up, a harvest cycle is initiated. This is important to
remember when performing diagnostic procedures
on the ice thickness control circuitry.
6-12
To allow the service technician to initiate a harvest
cycle without delay, this feature is not used on the
first cycle after moving the toggle switch OFF and
back to ICE.

MAXIMUM FREEZE TIME

The control system includes a built-in safety that
will automatically cycle the ice machine into
harvest after 60 minutes in the freeze cycle.

ICE THICKNESS CHECK

The ice thickness probe is factory-set to maintain
the ice bridge thickness at 1/8" (3.2 mm).
NOTE: Make sure the water curtain is in place
when performing this check. It prevents water
from splashing out of the water trough.
1. Inspect the bridge connecting the cubes. It
2. If adjustment is necessary, turn the ice
SV1589G
NOTE: Turning the adjustment 1/3 of a turn will
change the ice thickness about 1/16" (1.5 mm).
Make sure the ice thickness probe wire and the
bracket do not restrict movement of the probe.
should be about 1/8" (3.2 mm) thick.
thickness probe adjustment screw clockwise to
increase bridge thickness, or counterclockwise
to decrease bridge thickness.
ADJUSTING
SCREW
1/8" (3.2MM)
ICE
THICKNESS
Ice Thickness Check
Section 6
SV1208

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pd0522nPy0524nPd0532nPy0534n

Table of Contents