Installation

Remove Ice Thickness Probe Shipping Brackets

Remove and discard shipping brackets before starting the
ice machine.

Starting the Ice Machine

Step 1
Refer to cleaning and sanitizing procedure
and sanitize the ice machine and bin before placing in
operation.
Step 2
Press the power button to start ice-making.
NOTE: The water curtain/ice damper(s) must be in place on
the evaporator before the ice machine will start.
Refer to the sequence of operation in Section 3 for further
operational details.
Step 3
Observe a freeze and harvest cycle, then perform
an ice thickness check.
MINIMUM/MAXIMUM SLAB WEIGHT
Adjust ice thickness to meet chart specifications.
Model
i300
i320 - i450 - i520
i500 - i680 - i686 i690 - i696
i600 - i606
i850 - i870 - i890 - i976
i906 -i1000 - i1006 - i1070
i1200
i1090
i1400 - i1406
i1470
i1800
i1870 - i2170 - i2176
26
Minimum
Maximum
Ice Weight
Ice Weight
Per Cycle
Per Cycle
lbs
lbs
Grams
Grams
2.40 lbs
2.80 lbs
1089 grams
1270 grams
3.40 lbs
3.90 lbs
1542 grams
1769 grams
4.60 lbs
5.20 lbs
2087 grams
2359 grams
4.12 lbs
4.75 lbs
1869 grams
2155 grams
5.75 lbs
6.50 lbs
2608 grams
2948 grams
6.2 lbs
7.2 lbs
2812 grams
3266 grams
7.50 lbs
8.20 lbs
3402 grams
3719 grams
7.50 lbs
8.50 lbs
3402 grams
3856 grams
10.25 lbs
11.50 lbs
4649 grams
5216 grams
12.0 lbs
14.0 lbs
5443 grams
6350 grams
13.20 lbs
14.80 lbs
5987 grams
6713 grams
15.5 lbs
16.75 lbs
7031 grams
7598 grams

Ice Thickness Check

After a harvest cycle, inspect the ice cubes in the ice storage
bin. The ice thickness probe is factory-set to maintain the
ice bridge thickness at 3 mm (1/8").
NOTE: Make sure the water curtain is in place when
performing this check. It prevents water from splashing out
of the water trough.
1. Inspect the bridge connecting the cubes. It should be
about 3 mm (1/8") thick.
2. If adjustment is necessary, turn the ice thickness
probe adjustment screw clockwise to increase bridge
thickness, counterclockwise to decrease bridge
thickness. Set at 7 mm (9/32") gap between ice
thickness probe and evaporator as starting point, then
adjust to achieve a 3 mm (1/8") bridge thickness.
NOTE: Turning the adjustment one-third of a turn will
change the ice thickness about 1.5 mm (1/16").
ADJUSTING SCREW
3 mm (1/8")
ICE BRIDGE THICKNESS
PLACE 7 mm (9/32") DRILL BIT
HERE BETWEEN PROBE AND
EVAPORATOR TO SET INITIAL GAP
Ice Thickness Check
Make sure the ice thickness probe wire doesn't restrict