Parameter Access
5.3 DeviceNet Object Classes
5.3.1 Class ID 01h Identity Object
Class ID 01h identity object is a standard DeviceNet object for identification of the device (frequency converter). Set the
heartbeat interval in this object. The attributes supported for this class are listed in Table 5.3.
Attribute
1
5
5
2
3
4
5
6
7
10
Table 5.3 Class ID 0x01
5.3.2 Class ID 03h DeviceNet Object
Class ID 03h DeviceNet object is a standard DeviceNet object for configuration and status of the DeviceNet connection. The
attributes supported for this class are listed in Table 5.4.
Attribute
1
2
4
5
6
7
Table 5.4 Class ID 0x03
18
VLT
Access
Name
Get
Vendor
Get
Device Type
Get
Product Code
Get
Revision
Get
Status
Get
Serial Number
Get
Product Name
Get/Set
Heartbeat
Interval
Access
Name
Get/Set
MAC ID
Get/Set
Baud rate
Get
BOC
Get
Allocate
information
Get
MAC ID switch
changed
Get
Baud rate
switched from
last power-up
Danfoss A/S © 12/2015 All rights reserved.
®
DeviceNet MCA 104
Data type
Minimum/
Maximum
USINT
–
UNIT
–
UNIT
–
UNIT
–
UNIT
–
UDINT
–
String
–
USINT
0–255
Data type
Minimum/
Maximum
USINT
0–63
USINT
0–2
–
–
–
–
BOOL
0–1
BOOL
0–1
Units
Default
Description
–
97
Danfoss Drives Vendor
code.
–
2
AD/DC Motor.
–
100
See chapter 3.2.1 EDS File.
–
–
Software version on FC
102, FC 202, or FC 300.
–
–
–
–
From frequency
converter.
–
–
FC 100, FC 202, or FC
300.
s
0
Off.
Units
Default
Description
–
63
Node address.
–
0
0=125
1=250
2=500
–
–
Bus-off counter.
–
–
Only required if
predefined master/slave
is implemented.
–
0
The node address switch
has changed since the
last power-up/reset.
–
0
The baud rate switch has
changed since the last
power-up.
MG92F102