Troubleshooting
parameter 8-50 Coasting Select to parameter 8-56 Preset
Reference Select.
The effect of control mode after the function of
parameter 8-50 Coasting Select, parameter 8-51 Quick Stop
Select, and parameter 8-52 DC Brake Select are shown in
Table 8.3, Table 8.4, Table 8.5, and Table 8.6:
If [0] Digital input is selected, terminals control the coast
and DC brake functions.
Terminal
Bit 02/03/04
0
0
0
1
1
0
1
1
Table 8.3 Parameter 8-50/51/52 Setting: [0] Digital Input
If [1] Bus is selected, commands are activated only when
8
8
given via the control word.
Terminal
Bit 02/03/04
0
0
0
1
1
0
1
1
Table 8.4 Parameter 8-50/51/52 Setting: [1] Bus
If [2] Logic AND is selected, activate both signals to perform
the function.
Terminal
Bit 02/03/04
0
0
0
1
1
0
1
1
Table 8.5 Parameter 8-50/51/52 Setting: [2] Logic AND
If [3] Logic OR is selected, activation of 1 signal activates
the function.
Terminal
Bit 02/03/04
0
0
0
1
1
0
1
1
Table 8.6 Parameter 8-50/51/52 Setting: [3] Logic OR
NOTICE
Coasting, Quick Stop, and DC brake functions are active
for logic 0' .
42
®
VLT
DeviceNet MCA 104
Function
Coast/DC brake/Q-Stop
Coast/DC brake/Q-Stop
No Coast/DC brake/Q-Stop
No Coast/DC brake/Q-Stop
Function
Coast/DC brake/Q-Stop
No Coast/DC brake/Q-Stop
Coast/DC brake/Q-Stop
No Coast/DC brake/Q-Stop
Function
Coast/DC brake/Q-Stop
No Coast/DC brake/Q-Stop
No Coast/DC brake/Q-Stop
No Coast/DC brake/Q-Stop
Function
Coast/DC brake/Q-Stop
Coast/DC brake/Q-Stop
Coast/DC brake/Q-Stop
No Coast/DC brake/Q-Stop
Danfoss A/S © 12/2015 All rights reserved.
The effect of control mode after the function of
parameter 8-53 Start Select and parameter 8-54 Reversing
Select are shown in Table 8.7, Table 8.8, Table 8.9, and
Table 8.10:
If [0] Digital Input is selected, terminals control the start
and reversing functions.
Terminal
Bit 06/15
Function
0
0
Stop/Counter-clockwise
0
1
Stop/Counter-clockwise
1
0
Start/Clockwise
1
1
Start/Clockwise
Table 8.7 Parameter 8-53/54 Setting: [0] Digital input
If [1] Bus is selected, commands are activated only when
given via the control word.
Terminal
Bit 02/03/04
Function
0
0
Stop/Counter-clockwise
0
1
Start/Clockwise
1
0
Stop/Counter-clockwise
1
1
Start/Clockwise
Table 8.8 Parameter 8-53/54 Setting: [1] Bus
If [2] Logic AND is selected, activate both signals to perform
the function.
Terminal
Bit 02/03/04
Function
0
0
Stop/Counter-clockwise
0
1
Stop/Counter-clockwise
1
0
Stop/Counter-clockwise
1
1
Start/Clockwise
Table 8.9 Parameter 8-53/54 Setting: [2] Logic AND
If [3] Logic OR is selected, activation of 1 signal activates
the function.
Terminal
Bit 02/03/04
Function
0
0
Stop/Counter-clockwise
0
1
Start/Clockwise
1
0
Start/Clockwise
1
1
Start/Clockwise
Table 8.10 Parameter 8-53/54 Setting: [3] Logic OR
The effect of control mode after the function of
parameter 8-55 Set-up Select and parameter 8-56 Preset
Reference Select are shown in Table 8.11, Table 8.12,
Table 8.13, and Table 8.14:
If [0] Digital input is selected, the terminals control the set-
up and preset reference functions.
MG92F102