1769-If4 Input Image; 1769-If4 Configuration File; 1769-If4 Input Data File - Rockwell Automation 1769-IF4 User Manual

Compact i/o analog modules
Hide thumbs Also See for 1769-IF4:
Table of Contents

Advertisement

3-2
Module Data, Status, and Channel Configuration for the Input Modules

1769-IF4 Input Data File

Word/Bit
Word 0
Word 1
Word 2
Word 3
Word 4
Word 5
Publication 1769-UM002B-EN-P - July 2005

1769-IF4 Input Image

The 1769-IF4 input image file represents data words and status bits. Input
words 0 through 3 hold the input data that represents the value of the analog
inputs for channels 0 through 3. These data words are valid only when the
channel is enabled and there are no errors. Input words 4 and 5 hold the status
bits. To receive valid status information, the channel must be enabled.
TIP

1769-IF4 Configuration File

The configuration file contains information that you use to define the way a
specific channel functions. The configuration file is explained in more detail in
1769-IF4 Configuration Data File on page 3-4.
TIP
The input data table lets you access analog input module read data for use in
the control program, via word and bit access. The data table structure is shown
in table below.
Table 3.1 1769-IF4 Input Data Table
15
14
13
12
11
SGN
SGN
SGN
SGN
Not Used (Bits set to 0)
U0
O0
U1
O1
U2
You can access information in the input image file using
the programming software configuration screen.
Not all controllers support program access to the
configuration file. Refer to your controller's user manual.
10
9
8
7
6
Analog Input Data Value Channel 0
Analog Input Data Value Channel 1
Analog Input Data Value Channel 2
Analog Input Data Value Channel 3
O2
U3
O3
5
4
3
2
1
S3
S2
S1
Set to zero
0
S0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1769-if81769-of8v1769-of8c1769-of2

Table of Contents