13.4 High‐resolution volume and energy
High‐resolution volume and energy are available in the display and via serial communication. See below table.
Function
Display
Serially – from latest integration
Serially – interpolated instantaneous
value with the meter's time stamp
Please contact Kamstrup A/S for further information
13.5 Temperature calibration
The temperature measurement is adjusted and calibrated during the production process and it does not require
further adjustment in the meter's lifetime. The temperature circuit can only be adjusted in our factory.
13.6 Pulse interface
During test either optical reading head with USB plug (6699‐099) for serial reading of high‐resolution energy and
volume registers, or Pulse Interface (6699‐143) with optical reading head and connection unit for high‐resolution pulse
outputs is used. Do not forget that the meter must be in test mode.
Kamstrup A/S ∙ Technical description ∙ 5512‐1689_B1_GB_03.2017
Application
Standing start/stop
Standing start/stop
Flying start/stop
Value
Volume
Energy
Volume
Energy
Volume
Energy
MULTICAL® 403
Resolution
10 mL
1 Wh
10 mL
1 Wh
10 mL
1 Wh
117