MULTICAL® 403-W - Pt500 MULTICAL® 403-T - Pt500 MULTICAL® 403-V - Pt100 Battery for replacement Kamstrup type 403-0000-0000-200 (1 x D-cell) Kamstrup type 403-0000-0000-100 (2 x AA-cell) Communication Modules For an overview of available modules we refer to section 9, page 18.
MULTICAL® 403 1 General information Please read this guide carefully before mounting the energy meter. In case of incorrect mounting, Kamstrup's guarantee obligations no longer apply. Please note that the following installation conditions must be obeyed: - Pressure stage: PN16/PN25, see marking. The meter marking does not apply to enclosed accessories.
flow pipe. The short direct sensor can also be direct mounted in all Kamstrup flow sensors with G¾B, G1B, G5/4B and G2 thread on the meter case. Fasten the sensors’ brass unions lightly (approx. 4 Nm) using a 12 mm face wrench and seal the sensors with seal and locking wire.
Push the plastic sleeve on the sensor cable into the sensor pocket and secure the cable by means of the enclosed M4 sealing screw. Fasten the screw with your fingers only. Seal the pockets using seal and locking wire. Kamstrup A/S • 55121739_A3_GB_04.2016 Registered Address Reading Tel: +44 (0)118 9311188 | Email: info@able.co.uk...
flow direction is indicated by an arrow on the flow sensor. 3.1 Mounting of couplings, and short direct sensor in MULTICAL® 403 flow sensor The short direct sensor from Kamstrup may be installed in PN16 installations only. The blind plug which is mounted in the MULTICAL® 403 flow sensor from the factory can be used in...
(nominal flow) and minimum 2.5 bar at q (maximum flow). This applies to temperatures up to approx. 80 °C. The flow sensor must not be exposed to lower pressure than ambient pressure (vacuum). Kamstrup A/S • 55121739_A3_GB_04.2016 Registered Address Reading Tel: +44 (0)118 9311188 | Email: info@able.co.uk able.co.uk...
The flow sensor can be mounted horizontally, vertically, or at an angle. 90° 90° The flow sensor should be mounted at 0° and can be turned downwards to 90°. Kamstrup A/S • 55121739_A3_GB_04.2016 Registered Address Reading Tel: +44 (0)118 9311188 | Email: info@able.co.uk able.co.uk...
Flow from the right 3.5 Humidity and condensation If there is risk of condensation, e.g. in cooling systems, a condensation-proof MULTICAL® 403, type 403-T, must be used. Kamstrup A/S • 55121739_A3_GB_04.2016 Registered Address Reading Tel: +44 (0)118 9311188 | Email: info@able.co.uk able.co.uk ABLE Instruments &...
Note: For q 3.5 flow sensors and larger it is possible to demount the bracket from the flow sensor and use it as a wall bracket. Kamstrup A/S • 55121739_A3_GB_04.2016 Registered Address Reading Tel: +44 (0)118 9311188 | Email: info@able.co.uk able.co.uk ABLE Instruments &...
If the flow sensor is installed in a humid or condensing environment, the calculator must be wall mounted and positioned higher than the flow sensor. Kamstrup A/S • 55121739_A3_GB_04.2016 Registered Address Reading Tel: +44 (0)118 9311188 | Email: info@able.co.uk able.co.uk ABLE Instruments &...
The battery cannot and must not be charged and must not be short-circuited. Used batteries must be handed in for approved destruction, e.g. at Kamstrup A/S. Further details appear from document on handling and disposal of lithium batteries (5510-408).
230 VAC Supply cable Max. Fuse 2 x 0.75 mm (accessory from Kamstrup A/S) 230 VAC 2 x 1.0 mm 10 A This module is used when the meter is supplied directly by the mains.
PC program METERTOOL HCW. The resolutions of the pulse outputs always follow the least significant digit displayed for energy and volume respectively. Kamstrup A/S • 55121739_A3_GB_04.2016 Registered Address Reading Tel: +44 (0)118 9311188 | Email: info@able.co.uk able.co.uk...
24 and 25 using a twisted pair. The polarity is without importance for the functionality. The module is powered by the connected master. Kamstrup A/S • 55121739_A3_GB_04.2016 Registered Address Reading Tel: +44 (0)118 9311188 | Email: info@able.co.uk able.co.uk ABLE Instruments &...
9.8 Wireless M-Bus + pulse inputs, type HC-003-30* The wireless M-Bus module has been designed to form part of Kamstrup’s hand-held Wireless M-Bus Reader system, which operates within the unlicensed frequency band in the 868 MHz area. The radio module is available with either internal or external antenna.
*** q can only be changed in meters configured as meter type 6. Upon attempts to access this menu in meters configured with other country codes the display shows the message ”Off”. Kamstrup A/S • 55121739_A3_GB_04.2016 Registered Address Reading Tel: +44 (0)118 9311188 | Email: info@able.co.uk able.co.uk...
Page 23
Display readings are based on DDD-code 210. At kamstrup.com you find a selection of interactive user guides based on other DDD-codes. Registered Address Reading Tel: +44 (0)118 9311188 | Email: info@able.co.uk...