  • Page 1 Technical description ® MULTICAL 41 Water meter Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg TEL: +45 89 93 10 00 FAX: +45 89 93 10 01 info@kamstrup.com www.kamstrup.com...
  • Page 2 ® TECHNICAL DESCRIPTION MULTICAL 5512-313 GB/01.2010/Rev. C1...
  • Page 3: Table Of Contents

    ® TECHNICAL DESCRIPTION MULTICAL List of contents General Description ......................5 1.1 Mechanical construction……………………………………………………………………………………………………………………….6 Technical Data ........................7 2.1 Approved meter data…………………………………………………………………………………………………………………………….7 2.2 Electrical data……………………………………………………………………………………………………………………………………….7 2.3 Mechanical data……………………………………………………………………………………………………………………………………7 2.4 Accuracy……………………………………………………………………………………………………………………………………………….8 2.5 Materials………………………………………………………………………………………………………………………………………………8 Type Overview ........................9 ® 3.1 Type number, MULTICAL 41……………………………………………………………………………………………………………….10 3.2 PROG (A-B-CCC)…………………………………………………………………………………………………………………………………..11 3.3 CONFIG, DD-E-FF-GG…………………………………………………………………………………………………………………………….12 3.4 DATA…………………………………………………………………………………………………………………………………………………..13 3.5 Other functions……………………………………………………………………………………………………………………………………13...
  • Page 4 ® TECHNICAL DESCRIPTION MULTICAL Supply Modules ......................26 9.1 Built-in D-cell lithium battery……………………………………………………………………………………………………………….26 9.2 Supply module 230 VAC………………………………………………………………………………………………………………………27 9.3 Supply module 24 VAC………………………………………………………………………………………………………………………..27 9.4 Exchanging the supply unit………………………………………………………………………………………………………………….27 9.5 Mains supply cables……………………………………………………………………………………………………………………………28 10 Plug-in Modules ......................29 10.1 Data/pulse inputs (66-0R)…………………………………………………………………………………………………………………..29 10.2 M-Bus, EN 1434-3, EN 13757/pulse inputs (66-0P) M-Bus, EN 1434-3/ pulse inputs (66-0S)…………………………………………………………………………………………….30 10.3 Radio (66-0L)………………………………………………………………………………………………………………………………………31...
  • Page 5: General Description

    ® TECHNICAL DESCRIPTION MULTICAL 1 General Description ® MULTICAL 41 is a static water meter based on the ultrasonic principle. The water meter is based on experience gained since 1991 of development and production of static ultrasonic meters. The meter, which is intended for measurement of water comsumption in ”utility room environments”, has gone through a very extensive OIML R 49 type test to secure a long-term stable, accurate and reliable meter.
  • Page 6: Mechanical Construction

    ® TECHNICAL DESCRIPTION MULTICAL 1.1 Mechanical construction Figur 1 Transparent top cover with front plate Sealing screw for verification cover Verification cover including push button. The lid of the supply unit can be opened without breaking the verification Supply: Battery, 24 VAC or 230 VAC. Can be replaced without breaking the verification Case for electronics unit Screws and rawlplugs for brackets –...
  • Page 7: Technical Data

    ® TECHNICAL DESCRIPTION MULTICAL 2 Technical Data 2.1 Approved meter data OIML R 49 designation Accuracy class 2, environmental class B Flow sensor types Q3 = 1.6 m /h (see Table 1) Media temperature in flow sensor 0.1°C.…30°C Nom. Max. Min.
  • Page 8: Accuracy

    ® TECHNICAL DESCRIPTION MULTICAL 2.4 Accuracy MPE (Maximum Permissible Error). MPE according to OIML R 49 ± 5 % in the range Q1 ≤ Q ≤ Q2 ± 2 % in the range Q2 ≤ Q ≤ Q4 Diagram 1: OIML R 49 requirements to water meters 2.5 Materials Wetted parts Housing, gland...
  • Page 9: Type Overview

    ® TECHNICAL DESCRIPTION MULTICAL 3 Type Overview 3.1 Type number 66-Z?-??X-??? Flow sensor The type number of the flow sensor cannot be changed after programming at the factory. 3.2 PROG (total programming) A-B-CCC 3.3 CONFIG (partial programming) DD-E-FF-GG 3.4 DATA (partial programming) - Customer no.
  • Page 10: Type Number, Multical 41

    ® TECHNICAL DESCRIPTION MULTICAL ® 3.1 Type number, MULTICAL Type 66-Z Modules No module M-Bus/pulse inputs (secondary addressing) Data/pulse inputs M-Bus/pulse inputs (primary addressing) Radio/pulse output Radio with external antenna connection/pulse output Supply No module Battery, D-cell 230 VAC supply module 24 VAC supply module Flow sensor Q3 [m...
  • Page 11: Prog (A-B-Ccc)

    ® TECHNICAL DESCRIPTION MULTICAL 3.2 PROG (A-B-CCC) Programming number Flow sensor placing Internal value Measuring unit Internal value Flow sensor coding 3.2.1 Standard CCC-codes ® CCC-table for MULTICAL Number of decimals on the display CCC no. m³ Type [m³/h] 66-Zx-xxX-xxx 5512-313 GB/01.2010/Rev.
  • Page 12: Config, Dd-E-Ff-Gg

    ® TECHNICAL DESCRIPTION MULTICAL 3.3 CONFIG, DD-E-FF-GG 3.3.1 >DD< CONFIGURATION OF DISPLAY DD - codes >Primary< Level 1 Volume Hour counter Actual flow • 4 • 4 Peak flow (monthly) Yearly peak flow All info. All info., however (-2) DD - codes >Secondary<...
  • Page 13: Data

    ® TECHNICAL DESCRIPTION MULTICAL ® 3.3.2 >E< Configuration is not used for MULTICAL Set default at: 3.3.3 >FF< Input a, >GG< Input b, pulse separation (f ≤ 0.5 Hz) Input a Input b Terminal 65-66 Terminal 67-68 Max. input Max. input Measuring unit and decimal Pre-counter l/pulse...
  • Page 14: Dimensional Sketches

    ® TECHNICAL DESCRIPTION MULTICAL 4 Dimensional Sketches ® MULTICAL Figur 2: Mechanical dimensions of the electronic unit Figur 3: Flow sensor with G¾ and G1 thread connection Approx. Thread weight [kg] G¾ (Q3=1.6) 92.5 20.5 47.5 G1 (Q3=1.6) 92.5 20.5 47.5 Tabel 2: Total weight excluding packing 5512-313 GB/01.2010/Rev.
  • Page 15: Pressure Loss

    ® TECHNICAL DESCRIPTION MULTICAL 5 Pressure Loss According to OIML R 49 the max. pressure loss must not exceed 1.0 bar in the range Q1 to Q4. The pressure loss in a meter increases by the square of the flow and can be stated as: ×...
  • Page 16: Installation

    ® TECHNICAL DESCRIPTION MULTICAL 6 Installation 6.1 Installation requirements ® Before mounting MULTICAL 41, flush the system thoroughly with a fitting pipe mounted instead of the meter. Then remove the protection caps from the input and the output of the meter and mount the flow sensor with glands.
  • Page 17: Installation Angle For Multical 41

    ® TECHNICAL DESCRIPTION MULTICAL ® 6.2 Installation angle for MULTICAL ® MULTICAL 41 can be installed horizontally, vertically or at an angle. Figur 4 Important! ® MULTICAL 41 can be turned upwards to max. 45° and downwards to max. 90° in relation to the pipe axis.
  • Page 18: Straight Inlet

    ® TECHNICAL DESCRIPTION MULTICAL 6.3 Straight inlet ® MULTICAL 41, DN15 (G¾) and DN20 (G1): No requirements 6.4 Installation example ® Figur 7: Wall mounting of MULTICAL 5512-313 GB/01.2010/Rev. C1...
  • Page 19: The Calculator

    ® TECHNICAL DESCRIPTION MULTICAL 7 The Calculator 7.1 Measurement and calculation ® MULTICAL 41 uses time based integration, i.e. calculations of accumulated volume are carried out at fixed ® intervals irrespective of the actual water flow. In normal mode MULTICAL 41 has an integration interval of 28 sec., whereas in ”fast mode”...
  • Page 20: Display Functions

    ® TECHNICAL DESCRIPTION MULTICAL 7.3 Display functions No matter which display has been selected in the main menu or submenu, the display will automatically change into showing accumulated volume, when the front key has not been activated for 150 sec. Figur 9 The contents of both main and submenus are determined by the configuration selected for the meter (see section ®...
  • Page 21: Information Codes

    ® TECHNICAL DESCRIPTION MULTICAL 7.4 Information codes ® MULTICAL 41 is constantly checking a number of vital functions, whereby serious system errors can be detected. Should an error occur in the meter, the display will show and ”E” in the left side. In case of short-duration errors the ”E”...
  • Page 22: Reset Functions

    ® TECHNICAL DESCRIPTION MULTICAL 7.5 Reset functions ® MULTICAL 41 includes a “Power On Reset” circuit which is activated every time the supply voltage is switched on. This reset function only resets the internal high-resolution registers and therefore does not influence the display registers.
  • Page 23: The Flow Sensor

    Manufacturers of flow sensors have been working with alternative techniques to replace the mechanical principle. Research and development at Kamstrup have proven that ultrasonic metering is the most viable solution. Combined with microprocessor technology and piezo-ceramics, ultrasonic metering is not only accurate but also reliable.
  • Page 24 ® TECHNICAL DESCRIPTION MULTICAL In principle flow is obtained by measuring the flow velocity and multiplying it by the area of the measuring pipe: × where: is the flow is the flow velocity is the area of the measuring pipe The area and the length that the signal travels in the sensor are well-know factors.
  • Page 25: Signal Path

    ® TECHNICAL DESCRIPTION MULTICAL 8.4 Signal path Q3: 1.6 m³/h Parallel The sound path is parallel to the measuring pipe and is sent from the transducers via reflectors. 8.5 Flow limits In the meter’s working area from min. cut-off till far above Q4, there is a linear connection between the water volume flowing through and the water flow measured.
  • Page 26: Supply Modules

    Tabel 7 Above battery lifetimes apply to standard installations. The following may reduce the battery lifetime: Warm ambient temperature Frequent data communication Connection of data modules Fast mode For further details, please contact Kamstrup A/S. Figur 13 5512-313 GB/01.2010/Rev. C1...
  • Page 27: Supply Module 230 Vac

    ® TECHNICAL DESCRIPTION MULTICAL 9.2 Supply module 230 VAC This print module is galvanically separated from the mains supply and is suitable for direct mains installation. The module includes a double-chamber safety transformer that fulfils the requirements of double-insulation. The power consumption is less than 1 VA/1 W.
  • Page 28: Mains Supply Cables

    ® TECHNICAL DESCRIPTION MULTICAL 9.5 Mains supply cables ® MULTICAL 41 is available with mains supply cables for either 24 V or 230 V (l=1.5 m): Figur 16 Supply cable, type 5000-286 (2 x 0.75 mm²), max. 6 A fuse 5512-313 GB/01.2010/Rev.
  • Page 29: Plug-In Modules

    ® TECHNICAL DESCRIPTION MULTICAL 10 Plug-in Modules Type 66-Z Modules No module M-Bus/pulse inputs (secondary addressing) Data/pulse inputs M-Bus/pulse inputs (primary addressing) Radio/pulse output Radio with external antenna connection/pulse output 10.1 Data/pulse inputs (66-0R) Figur 17 Figur 18 The module includes a data connection which e.g. can be used for external data plug designed for use with the hand-held terminal MULTITERM or as a semi-permanent PC connection.
  • Page 30: M-Bus, En 1434-3, En 13757/Pulse Inputs (66-0P) M-Bus, En 1434-3/Pulse Inputs (66-0S)

    The pulse inputs on this module are identical with the ones described earlier. The Kamstrup M-Bus system is designed to meet the demands of the EN 1434-3 standard. For further information, see Technical Description for Kamstrup’s M-Bus system, 5511-709.
  • Page 31: Radio (66-0L)

    Furthermore, the module is mounted with a pulse output. The pulse output, which emits one pulse per 10 litres, is intended for CTS-systems. Power: 30 V Load: 10 mA Pulse duration: 0.1 seconds The pulse output is not active when delivered from Kamstrup. The jumper J4 must be removed in order to activate the pulse output. 5512-313 GB/01.2010/Rev. C1...
  • Page 32: Radio (66-0M)

    ® TECHNICAL DESCRIPTION MULTICAL 10.4 Radio (66-0M) Radio module with connection plug for external antenna to increase the range. Remaining functions are identical with the ones described earlier. Figure 25 Figure 26 5512-313 GB/01.2010/Rev. C1...
  • Page 33: Data Communication

    If necessary, use data cable 66-99-108 or Verification Equipment 66-99-385, in which the internal connection is integrated. Kamstrup reading head, type 66-99-102 connects to Kamstrup’s hand-held terminal, MULTITERM, and a standard IBM compatible PC with Windows 98 or newer versions.
  • Page 34: Data Strings

    66-CDE. The data strings are read via an optical reading head or via the data terminals on the plug-in modules. Please note that 300 baud is used at request and 1200 baud at data. For analytical purposes of /#5 monthly data, we recommend Kamstrup software METERTOOL LogView, type 66- 99-703. STANDARD DATA 1...
  • Page 35: Communication Driver

    ® TECHNICAL DESCRIPTION MULTICAL 11.4 Communication driver ® To develop your own software for data communication , e.g. between a PC and MULTICAL 41, below pseudo code can be used as a draft. The example shows a request for /#1: mscomm1.Settings = "300,E,7,2"...
  • Page 36: Calibration And Verification

    ® TECHNICAL DESCRIPTION MULTICAL 12 Calibration and Verification ® In order to be able to carry out test/verification of MULTICAL 41 at a minimum of time the meter has a testing mode. When the meter is in testing mode the program runs approx. 4 times faster than in standard mode. Testing mode also has some extra functions as described below.
  • Page 37: Testing Mode

    ® TECHNICAL DESCRIPTION MULTICAL 12.1 Testing mode Extra display readings In addition to the display readings in standard mode there is an extra testing counter/verification register for volume. The testing counter appears as extra readings immediately after the main counter for volume (Q). The resolution of the extra testing counter is for volume (Q’) 1 [ml].
  • Page 38: Pulse Interface For Multical 41

    ® TECHNICAL DESCRIPTION MULTICAL ® 12.2 Pulse Interface for MULTICAL When the meter is in testing mode, Pulse Interface type 66-99-109 can be used during verification on the test rigs with pulse interface. ® The pulse output on the terminals 6-7-8 cannot be used for testing MULTICAL Figure 28 3.5-30 VDC <...
  • Page 39: Approvals

    41 is type approved in Denmark according to OIML R 49-1:2003 and R 49-2:2004. The test reports, project 08-3417-VFMTY0403 and E820128, are made by FORCE and DELTA. For further information on type approvals and verification, please contact Kamstrup A/S. 22.36 OIML R49:2004 13.2 CE-Marking...
  • Page 40 ® TECHNICAL DESCRIPTION MULTICAL 5512-313 GB/01.2010/Rev. C1...
  • Page 41: Trouble Shooting

    ® TECHNICAL DESCRIPTION MULTICAL 14 Trouble Shooting ® MULTICAL 41 is constructed with a view to fast and simple installation as well as long-term, reliable operation at the water consumers. Should you, however, experience an operating problem with the meter, the error detection table below might help you clarify the possible cause.
  • Page 42: Disposal

    • Disposal made by Kamstrup A/S Kamstrup A/S is willing to dispose of worn out meters in an environmentally safe manner – please contact us before sending the meters.
  • Page 43: Documents

    ® TECHNICAL DESCRIPTION MULTICAL 16 Documents Danish English German Technical Description 5512-278 5512-313 Data sheet 5810-474 5810-487 5810-481 Installation guide 5512-277 5512-307 5512-309 User's manual 5512-276 5512-308 5512-310 5512-313 GB/01.2010/Rev. C1...
  • Page 44 ® TECHNICAL DESCRIPTION MULTICAL 5512-313 GB/01.2010/Rev. C1...