If parts other than those stated by us are used, water leaks, electric
shocks, fire and personal injury may occur as the unit may not work
properly.
Ventilate the working area well – refrigerant leakage may occur
during service work.
If the refrigerant comes into contact with naked flames, poisonous
gas is created.
Install the unit in a location with good support.
Unsuitable installation locations can cause the unit to fall and cause
material damage and personal injury. Installation without sufficient
support can also cause vibrations and noise.
Ensure that the unit is stable when installed, so that it can with-
stand earthquakes and strong winds.
Unsuitable installation locations can cause the unit to fall and cause
material damage and personal injury.
The electrical installation must be carried out by a qualified
electrician and the system must be connected as a separate cir-
cuit.
Power supply with insufficient capacity and incorrect function can
cause electric shocks and fire.
Use the stated cables for the electrical connection, tighten the
cables securely in the terminal blocks and relieve the wiring cor-
rectly to prevent overloading the terminal blocks.
Loose connections or cable mountings can cause abnormal heat pro-
duction or fire.
Check, after completed installation or service, that no refrigerant
leaks from the system in gas form.
If refrigerant gas leaks into the house and comes into contact with an
aerotemp, an oven or other hot surface, poisonous gases are produced.
Switch off the compressor before opening/breaching the refriger-
ant circuit.
If the refrigerant circuit is breached /opened whilst the compressor
is running, air can enter the process circuit. This can cause unusually
high pressure in the process circuit, which can cause bursts and per-
sonal injury.
Switch off the power supply in the event of a service or inspec-
tion.
If the power supply is not shut off, there is a risk of electric shocks
and damage due to the rotating fan.
Do not run the unit with removed panels or protection.
Touching rotating equipment, hot surfaces or high voltage parts can
cause personal injury due to entrapment, burns or electric shocks.
Cut the power before starting electrical work.
Failure to cut the power can cause electric shocks, damage and incor-
rect function of the equipment.
CARE
Carry out the electrical installation with care.
Do not connect the ground lead to the gas line, water line, lightning
conductor or telephone line's ground lead. Incorrect grounding can
cause unit faults such as electric shocks due to short-circuiting.
Use main switch with sufficient breaking capacity.
If the switch does not have sufficient breaking capacity, malfunctions
and fire can occur.
Always use a fuse with the correct rating in the locations where
fuses are to be used.
Connecting the unit with copper wire or other metal thread can cause
unit breakdown and fire.
Cables must be routed so that they are not damaged by metal
edges or trapped by panels.
Incorrect installation can cause electric shocks, heat generation and
fire.
Do not install the unit in close proximity to locations where
leakage of combustible gases can occur.
If leaking gases collect around the unit, fire may occur.
Do not install the unit where corrosive gas (for example nitrous
fumes) or combustible gas or steam (for example thinner and
petroleum gases) can build up or collect, or where volatile com-
bustible substances are handled.
Corrosive gas can cause corrosion to the heat exchanger, breaks in
plastic parts etc. and combustible gas or steam can cause fire.
Do not use the unit where water splashes may occur, for example
in laundries.
The indoor section is not waterproof and electric shocks and fire can
therefore occur.
NIBE AMS 10
Do not use the unit for specialist purposes such as for storing
food, cooling precision instruments, freeze-conservation of anim-
als, plants or art.
This can damage the items.
Do not install and use the system close to equipment that gener-
ates electromagnetic fields or high frequency harmonics.
Equipment such as inverters, standby sets, medical high frequency
equipment and telecommunications equipment can affect the unit
and cause malfunctions and breakdowns. The unit can also affect
medical equipment and telecommunications equipment, so that it
functions incorrectly or not at all.
Do not install the outdoor unit in the locations stated below.
- Locations where leakage of combustible gas can occur.
- Locations where carbon fibre, metal powder or other powder that
can enter the air.
- Locations where substances that can affect the unit, for example,
sulphide gas, chlorine, acid or alkaline substances can occur.
- Locations with direct exposure to oil mist or steam.
- Vehicles and ships.
- Locations where machines that generate high frequency harmonics
are used.
- Locations where cosmetic or special sprays are often used.
- Locations that can be subjected to direct salty atmospheres. In this
case, the outdoor unit must be protected against direct intakes of
salty air.
- Locations where large amounts of snow occur.
- Locations where the system is exposed to chimney smoke.
If the bottom frame of the outdoor section is corroded, or in any
other way damaged, due to long periods of operation, it must
not be used.
Using an old and damaged frame can cause the unit to fall and cause
personal injury.
If soldering near the unit, ensure that solder residue does not
damage the drip tray.
If solder residue enters the unit during soldering, small holes can ap-
pear in the tray resulting in water leakage. To prevent damage, keep
the indoor unit in its packing or cover it.
Do not allow the drainage pipe to exit into channels where pois-
onous gases, containing sulphides for example, can occur.
If the pipe exits into such a channel, any poisonous gases will flow
into the room and seriously affect the user's health and safety.
Insulate the unit's connection pipes so that the ambient air
moisture does not condense on them.
Insufficient insulation can cause condensation, which can lead to
moisture damage on the roof, floor, furniture and valuable personal
property.
Do not install the outdoor unit in a location where insects and
small animals can inhabit.
Insects and small animals can enter the electronic parts and cause
damage and fire. Instruct the user to keep the surrounding equipment
clean.
Take care when carrying the unit by hand.
If the unit weights more than 20 kg, it must be carried by two people.
Use gloves to minimize the risk of cuts.
Dispose of any packaging material correctly.
Any remaining packaging material can cause personal injury as it may
contain nails and wood.
Do not touch any buttons with wet hands.
This can cause electric shocks.
Do not touch any refrigerant pipes with your hands when the
system is in operation.
During operation the pipes become extremely hot or extremely cold,
depending on the method of operation. This can cause burn injuries
or frost injuries.
Do not shut off the power supply immediately after operation
has start.
Wait at least 5 minutes, otherwise there is a risk of water leakage or
breakdown.
Do not control the system with the main switch.
This can cause fire or water leakage. In addition, the fan can start un-
expectedly, which can cause personal injury.
Chapter 1 | Important information