Nibe AMS 10-8 Installer Manual

Nibe AMS 10-8 Installer Manual

Air/water heat pump

Advertisement

IHB EN 1826-3
331942
Air/water heat pump
NIBE AMS 10
INSTALLER MANUAL
6, 8, 12, 16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AMS 10-8 and is the answer not in the manual?

Questions and answers

Summary of Contents for Nibe AMS 10-8

  • Page 1 IHB EN 1826-3 INSTALLER MANUAL 331942 Air/water heat pump NIBE AMS 10 6, 8, 12, 16...
  • Page 3: Table Of Contents

    Removing the covers Item register 3 The heat pump design Contact information Component locations AMS 10-6 (EZ101) Component locations AMS 10-8 (EZ101) Component locations AMS 10-12 (EZ101) Component locations AMS 10-16 (EZ101) List of components AMS 10 (EZ101) Electrical panel...
  • Page 4: Important Information

    Do not allow children to clean or maintain the appliance unsupervised. Safety precautions This is an original manual. It may not be translated without the approval of NIBE. CAUTION Rights to make any design or technical modifications are reserved. Install the system in full accordance with this installation manual.
  • Page 5 Do not use the unit where water splashes may occur, for example in laundries. The indoor section is not waterproof and electric shocks and fire can therefore occur. NIBE AMS 10 Chapter 1 | Important information...
  • Page 6: Serial Number

    GWP value (Global Warming Potential) of 2088. Do not release R410A into the atmosphere. Caution You need the product’s service code and serial number for servicing and support. Chapter 1 | Important information NIBE AMS 10...
  • Page 7: Checklist: Checks Before Commissioning

    / control module.) KVR 10 When installing AMS 10-6 / HBS 05-6, check that the software version of the in- door module/control module is at least v8320. Cooling Notes Checked Pipe system, condensation insulation NIBE AMS 10 Chapter 1 | Important information...
  • Page 8: Compatible Indoor Modules (Vvm) And Control Modules (Smo)

    AMS 10 VVM 310 VVM 320 VVM 500 SMO 20 SMO 40 AMS 10-6 / HBS 05-6 AMS 10-8 / HBS 05-12 AMS 10-12 / HBS 05-12 AMS 10-16 / HBS 05-16 Indoor modules Control modules SMO 20 VVM 310...
  • Page 9: Delivery And Handling

    Condensation water must be led off to a drain or similar (see page10). • Care must be exercised so that the heat pump is not scratched during installation. NIBE AMS 10 Chapter 2 | Delivery and handling...
  • Page 10 The drain pan heater is supplied with power when one of the following conditions is met: The compressor has been in operation for at least 30 minutes after last start. The ambient temperature is lower than 1 °C. Chapter 2 | Delivery and handling NIBE AMS 10...
  • Page 11 Otherwise the stone caisson can be positioned directly under the heat pump. The outlet of the condensation water pipe must be at frost free depth. NIBE AMS 10 Chapter 2 | Delivery and handling...
  • Page 12 30 cm 30 cm Minimum free Minimum distance during use space of several AMS 10 However, the free space in front must be 100 cm for future servicing At least 100 cm Chapter 2 | Delivery and handling NIBE AMS 10...
  • Page 13: Removing The Covers

    Removing the covers AMS 10-6 AMS 10-8 NIBE AMS 10 Chapter 2 | Delivery and handling...
  • Page 14 AMS 10-12 AMS 10-16 Chapter 2 | Delivery and handling NIBE AMS 10...
  • Page 15: The Heat Pump Design

    3 The heat pump design Component locations AMS 10-6 (EZ101) PWB1 FM01 GQ10 XL53 XL52 EB11 QM36 QM37 XL20 NIBE AMS 10 Chapter 3 | The heat pump design...
  • Page 16: Component Locations Ams 10-8 (Ez101)

    Component locations AMS 10-8 (EZ101) PWB1 PWB2 PWB3 XL20 63H1 FM01 EEV-H EEV-C GQ10 XL53 QM36 XL52 EB11 QM37 EB10 XL20 Chapter 3 | The heat pump design NIBE AMS 10...
  • Page 17: Component Locations Ams 10-12 (Ez101)

    Component locations AMS 10-12 (EZ101) PWB3 PWB1 PWB2 63H1 FM01 XL20 EEV-C QM36 QM37 EB11 XL53 EEV-H XL52 GQ10 EB10 NIBE AMS 10 Chapter 3 | The heat pump design...
  • Page 18: Component Locations Ams 10-16 (Ez101)

    Component locations AMS 10-16 (EZ101) FM01 PWB3 PWB1 PWB2 63H1 EEV-C XL20 QM36 QM37 XL52 XL53 EEV-H EB11 FM02 EB10 GQ10 Chapter 3 | The heat pump design NIBE AMS 10...
  • Page 19: List Of Components Ams 10 (Ez101)

    Evaporator GQ10 (CM) Compressor QN1 (EEV-H) Expansion valve, heating QN2(20S) 4-way valve QN3 (EEV-C) Expansion valve, cooling MISCELLANEOUS Serial number plate Designations in component locations according to standard IEC 81346-2. NIBE AMS 10 Chapter 3 | The heat pump design...
  • Page 20: Electrical Panel

    AMS 10-8 Electrical panel PWB1 COMPONENT LOCATIONAMS 10 PWB2 AMS 10-6 PWB3 PWB1 Cable holder Cable holder Chapter 3 | The heat pump design NIBE AMS 10...
  • Page 21 Drain pan heater Fuse FM01 Fan motor PWB1 Control board PWB2 Inverter board PWB3 Filter board Terminal block, incoming supply and communica- tion Designations in component locations according to standard IEC 81346-2. NIBE AMS 10 Chapter 3 | The heat pump design...
  • Page 22: Sensor Placement

    Sensor placement POSITIONING THE TEMPERATURE SENSOR Outdoor moduleAMS 10-6 BT28 Incoming supply GQ10 EEV-H Outdoor moduleAMS 10-8/ AMS 10-12 BT28 Incoming supply Tho-A GQ10 EEV-H EEV-C Chapter 3 | The heat pump design NIBE AMS 10...
  • Page 23 QN1 (EEV-H) Expansion valve, heating QN2 (20S) 4-way valve QN3 (EEV-C) Expansion valve, cooling Tho-D Hot gas sensor Tho-R1 Evaporator sensor, out Tho-R2 Evaporator sensor, in Tho-S Suction gas sensor NIBE AMS 10 Chapter 3 | The heat pump design...
  • Page 24 DATA FOR SENSOR IN AMS 10-6 DATA FOR SENSOR IN AMS 10-8, -12, -16 Tho-D Tho-D Resistance Resistance Resitans Resitans (kΩ) (kΩ) (kΩ) (kΩ) Temperature Temperature Temperatur Temperatur (°C) (°C) (°C) (°C) Tho-A, R Tho-S, Tho-R1, Tho-R2 Resistance Resistance Resitans Resitans (kΩ)
  • Page 25: Pipe Connections

    4 Pipe connections NOTE For information: See chapter “Pipe connec- tions” in the Installer Manual for HBS 05. NIBE AMS 10 Chapter 4 | Pipe connections...
  • Page 26: Electrical Connections

    Check the maximum load in the table below. NOTE Outdoor module Maximum current (A) AMS 10-6 If the supply cable is damaged, only NIBE, its AMS 10-8 service representative or similar authorised AMS 10-12 person may replace it to prevent any danger AMS 10-16 and damage.
  • Page 27: Electrical Components

    * Only in a 3-phase installation. Electrical components See component location in chapter The heat pump design, Electrical panel on page 20. Accessibility, electrical connection REMOVING THE COVERS See chapter Removing the covers on page 13. NIBE AMS 10 Chapter 5 | Electrical connections...
  • Page 28: Connections

    To prevent interference, unscreened commu- nication and/or sensor cables to external con- nections must not be laid closer than 20 cm from high voltage cables. POWER CONNECTION AMS 10 Incoming supply Cable gland Chapter 5 | Electrical connections NIBE AMS 10...
  • Page 29 Incoming supply Cable gland NIBE AMS 10 Chapter 5 | Electrical connections...
  • Page 30 37 for the list of the accessories that can be used with AMS 10. NOTE For more information: See chapter “Electrical connections” in the Installer Manual for HBS 05. Chapter 5 | Electrical connections NIBE AMS 10...
  • Page 31: Commissioning And Adjusting

    “Start-up and inspection” in the Installer Manual for the indoor module or control module. NOTE For information: See chapter “Commissioning and adjustment” in the Installer Manual for HBS 05. NIBE AMS 10 Chapter 6 | Commissioning and adjusting...
  • Page 32: Control - Heat Pump Eb101

    7 Control - Heat pump EB101 NOTE For information: See chapter “Control – Heat pump EB101” in the Installer Manual for HBS 05. Chapter 7 | Control - Heat pump EB101 NIBE AMS 10...
  • Page 33: Disturbances In Comfort

    8 Disturbances in comfort NOTE For more information: See chapter “Disturb- ances in comfort” in the Installer Manual for HBS 05. NIBE AMS 10 Chapter 8 | Disturbances in comfort...
  • Page 34: Alarm List

    60 minutes continuously. • Insufficient air circulation or blocked heat exchanger • If the fault persists during cooling, there may be an insufficient amount of refriger- ant. • Defective control board in AMS 10 Chapter 9 | Alarm list NIBE AMS 10...
  • Page 35 Sensor fault, hot gas in AMS 10 (Tho-D). • Open circuit or short circuit on sensor input • Sensor does not work (see section "Dis- turbances in comfort") • Defective control board in AMS 10 NIBE AMS 10 Chapter 9 | Alarm list...
  • Page 36 Heat pump and indoor module (VVM) / • Outdoor module and indoor module air heat pump control module (SMO) do not work properly (VVM) / control module (SMO) are not together due to technical parameters. compatible. Chapter 9 | Alarm list NIBE AMS 10...
  • Page 37: Accessories

    1/4“ / 1/2”, 12 metres, insulated, for HBS05-6 and AMS 10-6 Part no. 067 591 3/8" – 5/8", 12 metres, insulated, for HBS 10-12/16 and AMS 10-8/12/16 Part no. 067 032 STAND AND BRACKETS Ground stand For AMS 10-6, -8, -12, -16 Part no.
  • Page 38: Technical Data

    11 Technical data Dimensions AMS 10-6 40º 40º Chapter 11 | Technical data NIBE AMS 10...
  • Page 39 Front Gas pipe Opening for pipe and wiring Liquid pipe Drainage hole AMS 10-8 30º 30º Above NIBE AMS 10 Chapter 11 | Technical data...
  • Page 40 Drainage hole AMS 10-12 Opening fo Right Chapter 11 | Technical data NIBE AMS 10...
  • Page 41 AMS 10-16 Drainage hole Fron Opening NIBE AMS 10 Chapter 11 | Technical data...
  • Page 42: Sound Pressure Levels

    Accordingly, you should always attempt to find Noise AMS 10-6 AMS 10-8 AMS 10-12 AMS 10-16 Sound power level, according to EN12102 at 7/35 °C (nominal)* Sound pressure level at 2 m free standing (nominal)* dB(A) * Free space.
  • Page 43: Technical Specifications

    Technical specifications IP 21 AMS 10 Outdoor module AMS 10-6 AMS 10-8 AMS 10-12 AMS 10-16 Outdoor Output data according to EN 14511 T5K temp./ Sup- ply temp. Heating -7/35 °C 2.57/0.56/4.60 2.68/0.41/6.60 2.75/0.31/9.00 2.80/0.23/12.10 (floor) Capacity / power input / COP (kW/kW/-) 7/35 °C...
  • Page 44 *AMS 10-6: If the length of the refrigerant pipes exceeds 15 m, extra refrigerant must be added at a rate of 0.02 kg/m. AMS 10-8/12/16: If the length of the refrigerant pipes exceeds 15 metres, extra refrigerant must be added at a rate of 0.06 kg/m.
  • Page 45 SCOP & PDESIGNH SCOP & P AMS 10 according to EN 14825 designh Outdoor module / SPLIT AMS 10-6 / AMS 10-8 / AMS 10-12 / AMS 10-16 / HBS 05-6 HBS 05-12 HBS 05-12 HBS 05-16 SCOP SCOP SCOP...
  • Page 46: Working Area

    Temperature 4,00 Temperatur (°C) (°C) 3,50 3,00 2,50 2,00 1,50 1,00 0,50 0,00 Utomhustemperatur 35°C Outdoor temperature (°C) 45°C (°C) 55°C Flow pipe Framledning Outdoor temperature Utomhustemperatur Return pipe (°C) Returledning (°C) Chapter 11 | Technical data NIBE AMS 10...
  • Page 47 Max. specified power AMS 10-8 Max. specified power AMS 10-12 Heating output Heating output Uppvärmningskapacitet Uppvärmningskapacitet (kW) (kW) (kW) (kW) 12,00 16,00 14,00 10,00 12,00 8,00 10,00 6,00 8,00 6,00 4,00 4,00 2,00 2,00 0,00 0,00 Utomhustemperatur Utomhustemperatur 35°C 35°C...
  • Page 48 25,00 20,00 15,00 10,00 5,00 0,00 Utomhustemperatur 35°C Outdoor temperature (°C) 45°C (°C) 55°C COP AMS 10-16 6,00 5,00 4,00 3,00 2,00 1,00 0,00 Utomhustemperatur Outdoor temperature 35°C (°C) 45°C (°C) 55°C Chapter 11 | Technical data NIBE AMS 10...
  • Page 49: Output With Lower Fuse Rating Than Recommended

    (°C) (°C) 45°C 55°C Capacity AMS 10-16, fuse rating 20A Heating output Uppvärmningskapacitet vid 20A avsäkring (kW) (kW) 25,00 20,00 15,00 10,00 5,00 0,00 Outdoor temperature Utomhustemperatur 35°C (°C) (°C) 45°C 55°C NIBE AMS 10 Chapter 11 | Technical data...
  • Page 50: Energy Labelling

    Energy labelling INFORMATION SHEET Supplier NIBE Model AMS 10-6 / HBS 05-6 AMS 10-8 / HBS 05- AMS 10-12 / HBS 05- AMS 10-16 / HBS 05- Temperature application °C 35 / 55 35 / 55 35 / 55 35 / 55...
  • Page 51 Nominal heating medium flow Annual energy consumption 3,248 Brine flow brine-water or water-water heat pumps Contact information NIBE Energy Systems – Box 14 – Hannabadsvägen 5 – 285 21 Markaryd – Sweden NIBE AMS 10 Chapter 11 | Technical data...
  • Page 52 Nominal heating medium flow 0.60 Annual energy consumption 4,447 Brine flow brine-water or water-water heat pumps Contact information NIBE Energy Systems – Box 14 – Hannabadsvägen 5 – 285 21 Markaryd – Sweden Chapter 11 | Technical data NIBE AMS 10...
  • Page 53 Nominal heating medium flow 0.86 Annual energy consumption 6,136 Brine flow brine-water or water-water heat pumps Contact information NIBE Energy Systems – Box 14 – Hannabadsvägen 5 – 285 21 Markaryd – Sweden NIBE AMS 10 Chapter 11 | Technical data...
  • Page 54 Nominal heating medium flow 1.21 Annual energy consumption 8,431 Brine flow brine-water or water-water heat pumps Contact information NIBE Energy Systems – Box 14 – Hannabadsvägen 5 – 285 21 Markaryd – Sweden Chapter 11 | Technical data NIBE AMS 10...
  • Page 55: Electrical Circuit Diagram

    Electrical circuit diagram AMS 10-6 AMS 10-8 230V ~ 50Hz POWER SOURCE 230V 50Hz F(20A) T2 T1 Y/GN F6 (5A) FM01 CNO2 (WH) (4A) 6 5 4 3 2 1 4 3 2 1 7 6 5 4 1 CNO1...
  • Page 56 (WH) (RD) (RD) (BK) (WH) t° t° t° t° t° t° 63H1 Tho-R1 Tho-D Tho-S Tho-A Tho-P Tho-R2 Two fan unit only AMS 10-16 POWER SOURCE 1 〜 230V 230V ~ 50Hz Chapter 11 | Technical data NIBE AMS 10...
  • Page 57 BT28 (Tho- Temperature sensor, outdoor air Tho-D Temperature sensor, hot gas Tho-R1 Temperature sensor, heat exchanger out Tho-R2 Temperature sensor, heat exchanger, in Tho-S Temperature sensor, suction gas Tho-P Temperature sensor, IPM NIBE AMS 10 Chapter 11 | Technical data...
  • Page 58 Chapter 11 | Technical data NIBE AMS 10...
  • Page 59: Item Register

    Information sheet, 50 Technical data, 38 Technical documentation, 51 Dimensions, 38 Energy rating, average climate, 45 Electrical circuit diagram, 55 Environmental information, 6 Energy labelling, 50 Energy rating, average climate, 45 Sound pressure levels, 42 General, 26 NIBE AMS 10 Item register...
  • Page 60 The heat pump design, 15 Component location AMS 10, 15 Component position electrical panel, 20 Electrical components AMS 10, 21 List of components AMS 10 (EZ101), 19 Transport and storage, 9 Troubleshooting Sensor placement, 22 Item register NIBE AMS 10...
  • Page 63: Contact Information

    Tel: +46 (0)433-27 3000 kuzmin@evan.ru info@nibe.se nibe-evan.ru nibe.se SWITZERLAND NIBE Wärmetechnik c/o ait Schweiz Industriepark, CH-6246 Altishofen Tel. +41 (0)58 252 21 00 info@nibe.ch nibe.ch For countries not mentioned in this list, contact NIBE Sweden or check nibe.eu for more information.
  • Page 64 WS release date: 2018-05-29 14:00 Publish date: 2018-08-20 15:24 This manual is a publication from NIBE Energy Systems. All product illustrations, facts and data are based on the available information at the time of the publication’s approval. NIBE Energy Systems makes reservations for any factual or printing errors in this manual.

This manual is also suitable for:

Ams 10-6Ams 10-12Ams 10-16Ams 10 series

Table of Contents