Do not allow children to clean or maintain the appliance unsupervised. Safety precautions This is an original manual. It may not be translated without the approval of NIBE. CAUTION Rights to make any design or technical modifications are reserved. Install the system in full accordance with this installation manual.
Page 5
Do not use the unit where water splashes may occur, for example in laundries. The indoor section is not waterproof and electric shocks and fire can therefore occur. NIBE AMS 10 Chapter 1 | Important information...
GWP value (Global Warming Potential) of 2088. Do not release R410A into the atmosphere. Caution You need the product’s service code and serial number for servicing and support. Chapter 1 | Important information NIBE AMS 10...
/ control module.) KVR 10 When installing AMS 10-6 / HBS 05-6, check that the software version of the in- door module/control module is at least v8320. Cooling Notes Checked Pipe system, condensation insulation NIBE AMS 10 Chapter 1 | Important information...
Condensation water must be led off to a drain or similar (see page10). • Care must be exercised so that the heat pump is not scratched during installation. NIBE AMS 10 Chapter 2 | Delivery and handling...
Page 10
The drain pan heater is supplied with power when one of the following conditions is met: The compressor has been in operation for at least 30 minutes after last start. The ambient temperature is lower than 1 °C. Chapter 2 | Delivery and handling NIBE AMS 10...
Page 11
Otherwise the stone caisson can be positioned directly under the heat pump. The outlet of the condensation water pipe must be at frost free depth. NIBE AMS 10 Chapter 2 | Delivery and handling...
Page 12
30 cm 30 cm Minimum free Minimum distance during use space of several AMS 10 However, the free space in front must be 100 cm for future servicing At least 100 cm Chapter 2 | Delivery and handling NIBE AMS 10...
Page 21
Drain pan heater Fuse FM01 Fan motor PWB1 Control board PWB2 Inverter board PWB3 Filter board Terminal block, incoming supply and communica- tion Designations in component locations according to standard IEC 81346-2. NIBE AMS 10 Chapter 3 | The heat pump design...
Page 23
QN1 (EEV-H) Expansion valve, heating QN2 (20S) 4-way valve QN3 (EEV-C) Expansion valve, cooling Tho-D Hot gas sensor Tho-R1 Evaporator sensor, out Tho-R2 Evaporator sensor, in Tho-S Suction gas sensor NIBE AMS 10 Chapter 3 | The heat pump design...
Page 24
DATA FOR SENSOR IN AMS 10-6 DATA FOR SENSOR IN AMS 10-8, -12, -16 Tho-D Tho-D Resistance Resistance Resitans Resitans (kΩ) (kΩ) (kΩ) (kΩ) Temperature Temperature Temperatur Temperatur (°C) (°C) (°C) (°C) Tho-A, R Tho-S, Tho-R1, Tho-R2 Resistance Resistance Resitans Resitans (kΩ)
Check the maximum load in the table below. NOTE Outdoor module Maximum current (A) AMS 10-6 If the supply cable is damaged, only NIBE, its AMS 10-8 service representative or similar authorised AMS 10-12 person may replace it to prevent any danger AMS 10-16 and damage.
* Only in a 3-phase installation. Electrical components See component location in chapter The heat pump design, Electrical panel on page 20. Accessibility, electrical connection REMOVING THE COVERS See chapter Removing the covers on page 13. NIBE AMS 10 Chapter 5 | Electrical connections...
To prevent interference, unscreened commu- nication and/or sensor cables to external con- nections must not be laid closer than 20 cm from high voltage cables. POWER CONNECTION AMS 10 Incoming supply Cable gland Chapter 5 | Electrical connections NIBE AMS 10...
Page 30
37 for the list of the accessories that can be used with AMS 10. NOTE For more information: See chapter “Electrical connections” in the Installer Manual for HBS 05. Chapter 5 | Electrical connections NIBE AMS 10...
“Start-up and inspection” in the Installer Manual for the indoor module or control module. NOTE For information: See chapter “Commissioning and adjustment” in the Installer Manual for HBS 05. NIBE AMS 10 Chapter 6 | Commissioning and adjusting...
7 Control - Heat pump EB101 NOTE For information: See chapter “Control – Heat pump EB101” in the Installer Manual for HBS 05. Chapter 7 | Control - Heat pump EB101 NIBE AMS 10...
8 Disturbances in comfort NOTE For more information: See chapter “Disturb- ances in comfort” in the Installer Manual for HBS 05. NIBE AMS 10 Chapter 8 | Disturbances in comfort...
60 minutes continuously. • Insufficient air circulation or blocked heat exchanger • If the fault persists during cooling, there may be an insufficient amount of refriger- ant. • Defective control board in AMS 10 Chapter 9 | Alarm list NIBE AMS 10...
Page 35
Sensor fault, hot gas in AMS 10 (Tho-D). • Open circuit or short circuit on sensor input • Sensor does not work (see section "Dis- turbances in comfort") • Defective control board in AMS 10 NIBE AMS 10 Chapter 9 | Alarm list...
Page 36
Heat pump and indoor module (VVM) / • Outdoor module and indoor module air heat pump control module (SMO) do not work properly (VVM) / control module (SMO) are not together due to technical parameters. compatible. Chapter 9 | Alarm list NIBE AMS 10...
1/4“ / 1/2”, 12 metres, insulated, for HBS05-6 and AMS 10-6 Part no. 067 591 3/8" – 5/8", 12 metres, insulated, for HBS 10-12/16 and AMS 10-8/12/16 Part no. 067 032 STAND AND BRACKETS Ground stand For AMS 10-6, -8, -12, -16 Part no.
Accordingly, you should always attempt to find Noise AMS 10-6 AMS 10-8 AMS 10-12 AMS 10-16 Sound power level, according to EN12102 at 7/35 °C (nominal)* Sound pressure level at 2 m free standing (nominal)* dB(A) * Free space.
Technical specifications IP 21 AMS 10 Outdoor module AMS 10-6 AMS 10-8 AMS 10-12 AMS 10-16 Outdoor Output data according to EN 14511 T5K temp./ Sup- ply temp. Heating -7/35 °C 2.57/0.56/4.60 2.68/0.41/6.60 2.75/0.31/9.00 2.80/0.23/12.10 (floor) Capacity / power input / COP (kW/kW/-) 7/35 °C...
Page 44
*AMS 10-6: If the length of the refrigerant pipes exceeds 15 m, extra refrigerant must be added at a rate of 0.02 kg/m. AMS 10-8/12/16: If the length of the refrigerant pipes exceeds 15 metres, extra refrigerant must be added at a rate of 0.06 kg/m.
Page 56
(WH) (RD) (RD) (BK) (WH) t° t° t° t° t° t° 63H1 Tho-R1 Tho-D Tho-S Tho-A Tho-P Tho-R2 Two fan unit only AMS 10-16 POWER SOURCE 1 〜 230V 230V ~ 50Hz Chapter 11 | Technical data NIBE AMS 10...
Page 57
BT28 (Tho- Temperature sensor, outdoor air Tho-D Temperature sensor, hot gas Tho-R1 Temperature sensor, heat exchanger out Tho-R2 Temperature sensor, heat exchanger, in Tho-S Temperature sensor, suction gas Tho-P Temperature sensor, IPM NIBE AMS 10 Chapter 11 | Technical data...
Page 58
Chapter 11 | Technical data NIBE AMS 10...
Tel: +46 (0)433-27 3000 kuzmin@evan.ru info@nibe.se nibe-evan.ru nibe.se SWITZERLAND NIBE Wärmetechnik c/o ait Schweiz Industriepark, CH-6246 Altishofen Tel. +41 (0)58 252 21 00 info@nibe.ch nibe.ch For countries not mentioned in this list, contact NIBE Sweden or check nibe.eu for more information.
Page 64
WS release date: 2018-05-29 14:00 Publish date: 2018-08-20 15:24 This manual is a publication from NIBE Energy Systems. All product illustrations, facts and data are based on the available information at the time of the publication’s approval. NIBE Energy Systems makes reservations for any factual or printing errors in this manual.
Need help?
Do you have a question about the AMS 10-8 and is the answer not in the manual?
Questions and answers