Table of Contents 1 Important information Installation data Safety information Service code and serial number AMS 10 – An excellent choice 2 The heat pump – the heart of the house Heat pump function Contact with AMS 10 Maintenance of AMS 10...
Serial number Service code Installation date Installer Always specify the service code and serial number Certification that the installation is carried out according to instructions in NIBE's installer manual and applicable regulations. Date __________________ Signed _________________________ Chapter 1 | Important information...
Page 6
The CE mark is obligatory for most products sold in the EU, regardless of where they are made. IP21 Classification of enclosure of electro-technical equipment. Danger to person or machine. Read the User Manual. Chapter 1 | Important information AMS 10...
Service code and serial number You can find the service code and the serial number (PF3) on the right- hand side of AMS 10. Chapter 1 | Important information AMS 10...
Nordic climate, which utilises the outdoor air as its energy source. AMS 10 together with a SPLIT box HBS 05 is intended for connection to water-borne heating systems and can both heat hot water effectively at high outdoor temperatures and provide high capacity to the heating sys- tem at low outdoor temperatures.
Page 9
■ Intelligent control via indoor module VVM or control module SMO AMS 10 together with SPLIT box HBS 05, is connected to the indoor module NIBE VVM with intelligent control or the control module SMO for optimum control of the heat pump.
-3 °C -3 °C 0 °C 2 °C Heat source Värmekälla The temperatures are only examples and may vary between different installations and time of year. Chapter 2 | The heat pump – the heart of the house AMS 10...
Page 11
The temperatures are only examples and may vary between different installations and time of year. Chapter 2 | The heat pump – the heart of the house AMS 10...
Contact with AMS 10 AMS 10 is controlled in various ways depending on your system. Your contact with the heat pump takes place via SPLIT box (HBS 05) and your indoor module (VVM) or control module (SMO). See relevant manual for more information.
Regular checks Your SPLIT box only requires minimal maintenance. The condensation hose should be checked to ensure that condensation can run out to a drain. If there is any suspicion of leakage, pipe connections on AMS 10 should be checked. NOTE Insufficient oversight can cause serious damage to AMS 10 which is not covered by the guarantee.
Page 14
Keep free of snow and ice Prevent snow from building up and covering the grilles and drain holes on AMS 10. Keep free of snow and/or ice. Chapter 2 | The heat pump – the heart of the house AMS 10...
The heat pump can be set to "silent mode", which reduces the heat pump's noise level. The function is useful when AMS 10 must be placed in noise sensitive areas. The function should only be used for limited periods as AMS 10 may not reach its dimensioned output.
Page 16
Engine block heater (Operation: 1 h/day, 4 months a year) Passenger compartment heater (Operation: 1 h/day, 4 months a year) These values are approximate example values. Chapter 2 | The heat pump – the heart of the house AMS 10...
Page 17
After 1-2 years the heating curve should be adjusted again, as well as the offset heating curve and the building's thermostat valves, because the heating system, as a rule, requires a lower temperature once the drying process is complete. Chapter 2 | The heat pump – the heart of the house AMS 10...
AMS 10 communicates all alarms to the indoor module/control module (VVM / SMO). Basic actions Make sure that the air flow to AMS 10 is not blocked by foreign objects. ■ Check that AMS 10 does not have any external damage.
4 Technical data Detailed technical specifications for this product can be found in the in- stallation manual (www.nibe.eu). Chapter 4 | Technical data AMS 10...
Charge coil A charge coil heats the domestic hot water (tap water) in the water heater with heating water (heating medium) from AMS 10. Charge pump See "Circulation pump". Circulation pump Pump that circulates liquid in a pipe system.
Page 21
Evaporator Heat exchanger where the refrigerant evaporates by retrieving heat energy from the air which then cools. Chapter 5 | Glossary AMS 10...
A low pressure pressostat trips if the evaporation pressure is too low. Radiator Another word for heating element. They must be filled with water in order to be used with AMS 10. Chapter 5 | Glossary AMS 10...
Supply temperature The temperature of the heated water sent by the heat pump to the heating system. Water heater Container where domestic water is heated. Is located somewhere outside the heat pump. Chapter 5 | Glossary AMS 10...
Tel: +7 831 419 57 06 E-mail: kuzmin@evan.ru www.nibe-evan.ru NIBE AB Sweden, Box 14, Hannabadsvägen 5, SE-285 21 Markaryd Tel: +46 (0)433 73 000 E-mail: info@nibe.se www.nibe.se For countries not mention in this list, please contact Nibe Sweden or check www.nibe.eu for more information.