Nibe AMS 10 Series Installer Manual

Nibe AMS 10 Series Installer Manual

Air/water heat pump
Hide thumbs Also See for AMS 10 Series:

Advertisement

Installer manual
AMS 10
AMS 10-6 / 10-8 / 10-12 / 10-16
Air/water heat pump
IHB EN 1749-2
331942

Advertisement

Table of Contents
loading

Summary of Contents for Nibe AMS 10 Series

  • Page 1 Installer manual AMS 10 AMS 10-6 / 10-8 / 10-12 / 10-16 Air/water heat pump IHB EN 1749-2 331942...
  • Page 3: Table Of Contents

    Table of Contents 1 Important information System solution Safety information Serial number Recovery Environmental information Checklist: Checks before commissioning 2 Delivery and handling Transport and storage Assembly Removing the covers 3 The heat pump design Component locationAMS 10 Electrical panel Sensor placement 4 Pipe connections 5 Electrical connections...
  • Page 4: Important Information

    Marking System solution The CE mark is obligatory for most products sold AMS 10 is intended for installation with NIBE SPLIT Box HBS 05 and indoor module (VVM) or control in the EU, regardless of where they are made. module (SMO) for a complete system solution.
  • Page 5 If the power supply is not shut off, there is a risk of electric shocks If soldering near the unit, ensure that solder residue does not and damage due to the rotating fan. damage the drip tray. If solder residue enters the unit during soldering, small holes can Do not run the unit with removed panels or protection.
  • Page 6: Serial Number

    Serial number Caution You need the product’s service code and serial You can find the service code and the serial number (PF3) number for servicing and support. on the right-hand side of AMS 10. Recovery Leave the disposal of the packaging to the in- staller who installed the product or to special waste stations.
  • Page 7: Checklist: Checks Before Commissioning

    Checklist: Checks before commissioning Refrigerant system Notes Checked Pipe length Height difference Pressurization test Leak testing End pressure vacuum Pipe insulation Electrical installation Notes Checked Property's main fuse Group fuse Load monitor / current sensor (Connects to indoor module / control module.) KVR 10 When installing AMS 10-6 / HBS 05-6, check that the software version of the in-...
  • Page 8: Delivery And Handling

    2 Delivery and handling Transport and storage AMS 10 must be transported and stored vertically. NOTE Ensure that the heat pump cannot fall over during transport. Assembly Place AMS 10 outdoors on a solid level base that can ■ take the weight, preferably a concrete foundation. If concrete slabs are used they must rest on asphalt or shingle.
  • Page 9 Lift from the street to the set up location Condensation run off If the base allows, the simplest thing is to use a pallet Condensation runs out on to the ground below AMS 10. truck to move the AMS 10 to the set up location. To avoid damage to the house and heat pump, the condensation must be gathered and drained away.
  • Page 10 Gutter drainage Recommended alternative for leading off condensation water NOTE Drain indoors Bend the hose to create a water seal, see illus- tration. Joint Water seal Water seal Frost free Frostfritt depth djup From air/water heat The condensation water is lead to an indoor drain (sub- pump ject to local rules and regulations).
  • Page 11 Installation area The recommended distance between AMS 10 and the house wall must be at least 15 cm. Clearance above AMS 10 should be at least 100 cm. However, free space in front must be 100 cm for future servicing 15 cm Free space behind 30 cm...
  • Page 12: Removing The Covers

    Removing the covers AMS 10-6 AMS 10-8 AMS 10-12 Chapter 2 | Delivery and handling AMS 10...
  • Page 13 AMS 10-16 AMS 10 Chapter 2 | Delivery and handling...
  • Page 14: The Heat Pump Design

    3 The heat pump design Component locationAMS 10 Component locations AMS 10-6 (EZ101) PWB1 FM01 GQ10 XL53 XL52 EB11 QM36 QM37 XL21 Chapter 3 | The heat pump design AMS 10...
  • Page 15 Component locations AMS 10-8 (EZ101) PWB1 PWB2 PWB3 XL21 63H1 FM01 EEV-H EEV-C GQ10 XL53 QM35 XL52 QM36 EB11 XL21 AMS 10 Chapter 3 | The heat pump design...
  • Page 16 Component locations AMS 10-12 (EZ101) PWB3 PWB1 PWB2 63H1 FM01 XL21 EEV-C QM35 QM36 XL53 EEV-H EB11 XL52 GQ10 Chapter 3 | The heat pump design AMS 10...
  • Page 17 Component locations AMS 10-16 (EZ101) FM01 PWB3 PWB1 PWB2 63H1 EEV-C XL21 QM35 QM36 XL52 XL53 EEV-H EB11 FM02 GQ10 AMS 10 Chapter 3 | The heat pump design...
  • Page 18 List of components AMS 10 (EZ101) 4-way valve 63H1 High pressure pressostat CM (GQ10) Compressor DH (EB11) Drain pan heater EEV (QN1) Expansion valve, cooling EEV-H (QN2) Expansion valve, heating FM01 (GQ1) FM02 (GQ2) Low pressure transmitter PWB1 Control board PWB2 Inverter board PWB3...
  • Page 19: Electrical Panel

    AMS 10-8 Electrical panel PWB1 Component locationAMS 10 PWB2 AMS 10-6 PWB1 PWB3 Cable holder Cable holder AMS 10 Chapter 3 | The heat pump design...
  • Page 20 Främre el Främre el AMS 10-12 / AMS 10-16 PWB3 PWB1 FM01 Bakre el Diode module Bakre el Reactor AF module Capacitor PWB2 Electrical components AMS 10 Compressor heater Drain pan heater Fuse FM01 Fan motor PWB1 Control board PWB2 Inverter board PWB3 Filter board...
  • Page 21: Sensor Placement

    Sensor placement Positioning the temperature sensor Outdoor moduleAMS 10-6 BT28 Incoming supply GQ10 EEV-H Outdoor moduleAMS 10-8/ AMS 10-12 BT28 Incoming supply GQ10 EEV-H EEV-C AMS 10 Chapter 3 | The heat pump design...
  • Page 22 Outdoor moduleAMS 10-16 BT28 Incoming supply GQ10 EEV-H EEV-C BE1 (CT) Current sensor BT28 (Tho-A) Temperature sensor, outdoor air BP1 (63H1) High pressure pressostat BP2 (LPT) Pressure sensor, low pressure GQ1 (FM01) GQ2 (FM02) GQ10 (CM) Compressor QN1 (EEV-H) Expansion valve, heating QN2 (20S) 4-way valve QN3 (EEV-C)
  • Page 23 Data for sensor in AMS 10-6 Data for sensor in AMS 10-8, -12, -16 Tho-D Tho-D Motstånd Motstånd Resistor Resistor (kΩ) (kΩ) 90 100 110 120 130 140 150 Tho-D Temperatur (°C) Temperature (°C) Tho-D Temperature (°C) Temperatur (°C) Tho-A, R Tho-S, Tho-R1, Tho-R2 Motstånd Resistor...
  • Page 24: Pipe Connections

    4 Pipe connections NOTE For information: See chapter “Pipe connec- tions” in the Installer Manual for HBS 05. Chapter 4 | Pipe connections AMS 10...
  • Page 25: Electrical Connections

    This means that one of the phases will be loaded with a number of amperes (A) during compressor operation. NOTE Check the maximum load in the table below. If the supply cable is damaged, only NIBE, its Outdoor module Maximum current (A) service representative or similar authorised...
  • Page 26: Electrical Components

    Incoming supply distribution unit Isolator switch Communication cable Power cable *Current sensor HBS 05 NIBE VVM AMS 10 * Only in a 3-phase installation. Electrical components See component location in chapter The heat pump design, Electrical panel on page 19. Accessibility, electrical...
  • Page 27: Connections

    Connections NOTE To prevent interference, unscreened commu- nication and/or sensor cables to external con- nections must not be laid closer than 20 cm from high voltage cables. Power connection AMS 10 Incoming supply Cable gland AMS 10 Chapter 5 | Electrical connections...
  • Page 28 Incoming supply Cable gland Chapter 5 | Electrical connections AMS 10...
  • Page 29 Communication connection Communication is connected on terminal block TB. See also electrical wiring diagram on page 56. You can find more information in the Installer Manual for SPLIT box HBS 05. Connecting accessories Instructions for connecting accessories are in the install- ation instructions provided for the respective accessory.
  • Page 30: Commissioning And Adjusting

    6 Commissioning and adjusting Compressor heater AMS 10 is equipped with a compressor heater (CH) that heats the compressor before start-up and when the compressor is cold. (Does not apply to AMS 10-6.) NOTE The compressor heater must have been connec- ted for 6 –...
  • Page 31: Control - Heat Pump Eb101

    7 Control - Heat pump EB101 NOTE For information: See chapter “Control – Heat pump EB101” in the Installer Manual for HBS 05. AMS 10 Chapter 7 | Control - Heat pump EB101...
  • Page 32: Disturbances In Comfort

    8 Disturbances in comfort NOTE For more information: See chapter “Disturb- ances in comfort” in the Installer Manual for HBS 05. Chapter 8 | Disturbances in comfort AMS 10...
  • Page 33: Alarm List

    9 Alarm list Alarm Alarm text on the dis- Description May be due to play ■ High condenser out Too high temperature out from the con- Low flow during heating operation denser. Self-resetting. ■ Too high set temperatures ■ High condenser in Too high temperature into the condenser.
  • Page 34 Alarm Alarm text on the dis- Description May be due to play ■ High temperature in heat Temperature deviation on the heat ex- Sensor does not work (see section "Dis- exchanger changer sensor (Tho-R1/R2) five times turbances in comfort") within 60 minutes or for 60 minutes con- ■...
  • Page 35 Alarm Alarm text on the dis- Description May be due to play ■ Sensor fault Tho-D Sensor fault, hot gas in AMS 10 (Tho-D). Open circuit or short circuit on sensor input ■ Sensor does not work (see section "Dis- turbances in comfort") ■...
  • Page 36: Accessories

    10 Accessories Not all accessories are available on all markets. Indoor module VVM 310 Air/water heat pump Part no. 069 430 SPLIT box HBS 05 HBS 05-6 VVM 310 Part no. 067 578 With integrated EMK 310 HBS 05-12 Part no.067 480 Part no.
  • Page 37 Stand and brackets Ground stand For AMS 10-6, -8, -12, -16 Part no. 067 515 Wall bracket For AMS 10-6, -8, -12 Part no. 067 600 AMS 10 Chapter 10 | Accessories...
  • Page 38: Technical Data

    11 Technical data Dimensions AMS 10-6 40º 40º Chapter 11 | Technical data AMS 10...
  • Page 39 Right Front Gas pipe Opening for pipe and wiring Liquid pipe Drainage hole AMS 10-8 30º 30º Above AMS 10 Chapter 11 | Technical data...
  • Page 40 Drainage ho AMS 10-12 Opening Right Chapter 11 | Technical data AMS 10...
  • Page 41 AMS 10-16 Drainage ho Openin AMS 10 Chapter 11 | Technical data...
  • Page 42: Sound Pressure Levels

    The sound pressure levels are further affected by walls, Sound pressure levels bricks, differences in ground level, etc and should therefore only be seen as guide values. AMS 10 is usually placed next to a house wall, which gives a directed sound distribution that should be con- sidered.
  • Page 43: Technical Specifications

    Technical specifications IP 21 Outdoor module AMS 10-6 AMS 10-8 AMS 10-12 AMS 10-16 Output data Heating Outdoor Nominal Nominal Nominal Nominal temp./ Supply temp. 2.67/0.5/5.32 3.86/0.83/4.65 5.21/1.09/4.78 7.03/1.45/4.85 Output data according to 7/35 °C (floor) EN14511 T5K 2/35 °C 2.32/0.55/4.2 5.11/1.36/3.76 6.91/1.79/3.86...
  • Page 44 Outdoor module AMS 10-6 AMS 10-8 AMS 10-12 AMS 10-16 Dimensions, refrigerant pipe Gas pipe: Gas pipe: OD15.88 (5/8") OD12.7 (1/2") Fluid pipe: OD9.52 (3/8") Fluid pipe: OD6.35 (1/4") Pipe connections Pipe connection option Right-hand side Right-hand side Bottom / Bottom / right-hand side / right-hand...
  • Page 45 SCOP & Pdesign SCOP & Pdesign AMS 10 according to EN 14825 Outdoor module / AMS 10-6 / AMS 10-8 / AMS 10-12 / AMS 10-16 / SPLIT box HBS 05-6 HBS 05-12 HBS 05-12 HBS 05-16 Pdesign SCOP Pdesign SCOP Pdesign SCOP...
  • Page 46 Working range, compressor operation - heating AMS 10 Heating mode Water temperature °C Vattentemperatur (°C) Utomhustemperatur (°C) Supply temperature Outdoor air temperature °C Framledning Return temp Returledning During shorter time it is allowed to have lower working temperatures on the water side, e.g. during start up. Framledning Returledning Vattentemperatur (°C)
  • Page 47 Utomhustemperatur (°C) Working range, compressor operation - cooling AMS 10 Cooling mode Water temperature °C Vattentemperatur (°C) Utomhustemperatur (°C) Supply temperature Outdoor air temperature °C Framledning Return temp Returledning Framledning Returledning AMS 10 Chapter 11 | Technical data...
  • Page 48 Max. specified power AMS 10-8 Output and COP at different supply F2040-8 Max avgiven effekt temperatures Heating output (kW) Heating output (kW) Uppvärmningskapacitet (kW) 12,00 Maximum capacity including defrosting. 10,00 Max. specified power AMS 10-6 F2040-6 Max avgiven effekt 8,00 Heating output (kW) Heating output (kW) Uppvärmningskapacitet (kW)
  • Page 49 Max. specified power AMS 10-12 Max. specified power AMS 10-16 F2040-12 Max avgiven effekt F2040-16 Max avgiven effekt Heating output (kW) Heating output (kW) Heating output (kW) Heating output (kW) Uppvärmningskapacitet (kW) Uppvärmningskapacitet (kW) 16,00 25,00 14,00 20,00 12,00 10,00 15,00 8,00 10,00...
  • Page 50 Output with lower fuse rating than recommended Capacity AMS 10-12, fuse rating 16A Avgiven effekt F2040-12, avsäkring 16A Heating output (kW) Heating output (kW) Uppvärmningskapacitet (kW) 16,00 14,00 12,00 10,00 8,00 6,00 4,00 2,00 0,00 Outdoor temperature (°C) Utomhustemperatur (°C) Supply temperature (°C) Framledningstemperatur (°C) Capacity AMS 10-12, fuse rating 20A...
  • Page 51: Energy Labelling

    Energy labelling Information sheet Supplier NIBE Model AMS 10-6 / HBS 05- AMS 10-8 / HBS 05- AMS 10-12 / HBS AMS 10-16 / HBS 05-12 05-16 Temperature application °C 35 / 55 35 / 55 35 / 55 35 / 55...
  • Page 52 35 / 51 Nominal heating medium flow Annual energy consumption 3,248 Brine flow brine-water or water-water heat pumps Contact information NIBE Energy Systems – Box 14 – Hannabadsvägen 5 – 285 21 Markaryd – Sweden Chapter 11 | Technical data AMS 10...
  • Page 53 Nominal heating medium flow 0.60 Annual energy consumption 4,447 Brine flow brine-water or water-water heat pumps Contact information NIBE Energy Systems – Box 14 – Hannabadsvägen 5 – 285 21 Markaryd – Sweden AMS 10 Chapter 11 | Technical data...
  • Page 54 Nominal heating medium flow 0.86 Annual energy consumption 6,136 Brine flow brine-water or water-water heat pumps Contact information NIBE Energy Systems – Box 14 – Hannabadsvägen 5 – 285 21 Markaryd – Sweden Chapter 11 | Technical data AMS 10...
  • Page 55 Nominal heating medium flow 1.21 Annual energy consumption 8,431 Brine flow brine-water or water-water heat pumps Contact information NIBE Energy Systems – Box 14 – Hannabadsvägen 5 – 285 21 Markaryd – Sweden AMS 10 Chapter 11 | Technical data...
  • Page 56: Electrical Circuit Diagram

    Electrical circuit diagram AMS 10-6 AMS 10-8 230V ~ 50Hz POWER SOURCE 230V 50Hz F(20A) T2 T1 Y/GN F6 (5A) FM01 CNO2 (WH) (4A) 6 5 4 3 2 1 4 3 2 1 7 6 5 4 1 CNO1 CNW2 CNEEV2 CNEEV1...
  • Page 57 AMS 10-12 POWER SOURCE 1 〜 230V 230V ~ 50Hz Y/GN F (30A) F (8A) NOISE FILTER PWB3 F (4A) FM01 FM02 + − 4 3 2 1 4 3 2 1 7 6 5 4 1 7 6 5 4 1 CNW2 CNEEV1 CNEEV2...
  • Page 58 AMS 10-16 POWER SOURCE 1 〜 230V 230V ~ 50Hz Chapter 11 | Technical data AMS 10...
  • Page 59 Designa- Description tion Solenoid for 4-way valve 52X1 Auxiliary relay (for CH) 52X2 Auxiliary relay (for DH) 52X3 Auxiliary relay (for 20S) 52X4 Auxiliary relay (for SV1) 63H1 High pressure pressostat Capacitor Compressor heater Compressor motor CnA~Z Terminal block Current sensor Drain pan heater Diode module Fuse...
  • Page 60: Item Register

    12 Item register Item register Environmental information, 6 Marking, 4 Accessibility, electrical connection, 26 Safety precautions, 4 Accessories, 36 Serial number, 6 Alarm list, 33 Symbols, 4 Assembly, 8 Symbols on AMS 10, 4 Safety precautions, 4 Sensor placement, 21 Checklist: Checks before commissioning, 7 Serial number, 6 Commissioning and adjusting, 30...