Globalstar SmartOne Series User Manual page 63

Satellite managed asset ready tracker
Table of Contents

Advertisement

Contact Service Provider message unless the fault is determined to have
cleared, and then determined to have come back again. The Contact
Service Provider message is shown in table 10.
Byte Number
Variable
0
Type Field
0
Subtype
Number of
1
transmissions
per burst.
1
Battery
Condition
1
GPS Subsystem
Fault
1
Transmitter
Subsystem Fault
1
Scheduler
Subsystem Fault
2
Min Interval
3
Max Interval
4
GPS Mean Search
Time
5,6
# GPS Fails
7,8
# Transmissions
SmartOne Manual Rev 1.5
Bits
Description
Bit (1:0) = 3 Non Standard
2
message type:
Bit (7:2) = 23 Contact Service
6
Provider Message
Bits(3:0) = Number of
4
Transmissions (1 to 15
Transmissions)
Bit 4: 0 = Good battery. 1 =
1
Replace Battery
Bit 5: 0 = GPS system OK. 1 =
1
Fault
Bit 6: 0 = Transmitter OK. 1 =
1
Fault.
1
Bit 7: 0 = OK. 1 = Fault
Minimum Interval between
transmission attempts ( 5
8
second resolution) Default is
300 seconds
Maximum Interval between
8
transmission attempts, Default
is 600 seconds
Unsigned binary count in
8
seconds for mean GPS search to
acquire
Unsigned binary count of
16
failed GPS attempts since last
Diagnostic message
# of transmissions since last
16
Diagnostic message
Table 10 - Contact Service Provider Message