Detection Of Spindle With Inverse Behavior - BONFIGLIOLI ACTIVE CUBE Applications Manual

Spindle drive frequency inverter 230 v / 400 v
Hide thumbs Also See for ACTIVE CUBE:
Table of Contents

Advertisement

5.1.4

Detection of spindle with inverse behavior

During setup, a PMSM with an angle deviating by 180 degrees (electrical) can be identified as an in-
verse machine. Such machines are typically PMSM with buried magnets.
For identification, a part of the flux direction identification normally carried out upon startup of a
standing machine (depending on setting of Parameter 645, see Chapter 5.1.1.3 "Determination of the
flux direction at startup") is carried out during parameter identification.
Parameter
Estimation of flux-direction - inverted
machine:
− "0-Off" when a "normal" machine is identified
− "1-On" when a "inverse" machine is identified
If, for example, reliable identification is not possible due to rotation of the machine during parameter
identification, Parameter 644 will remain unchanged.
Parameter
No.
Identifier
644
estimation of flux-direction - inverted
11/13
644 is set as follows depending on the identified
Unit
Setting range
-
ACU
Spindle Applications
Default settings
0-Off
1-On
0-Off
35

Advertisement

Table of Contents
loading

Table of Contents