Siemens SINUMERIK 840D sl Manual page 52

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

General information and networking
1.4 Networking
● "Machine control panel address - MCP" (0-255)
This specifies the address of the associated MCP. It matches the [Station] mcpIndex setting
from config.ini.
● "Electronic key system index - EKS" (0-255)"
This specifies the index of the associated EKS. It matches the [Station] eksIndex setting
from config.ini.
● "Enable direct keys" (yes/no)
This specifies whether direct keys (if present) should communicate with the PLC (yes) or
be treated as ordinary keys (no).
"OK" saves any modified values to the config.ini file or to the Flashstore (HT 8 individual mode).
Parameters for the "config.ini" file
Two steps need to be performed:
1. Select "New" or "Replacement for existing panel".
2. Select what is to be replaced.
When an unknown TCU (i.e. not yet registered with the boot server) is started, a selection
menu containing both the "New" and "Replacement for existing panel" items will appear. The
accessibility of all the registered TCUs is tested in the background.
The status of this test process appears in the message line: "(0/3 panels inactive)".
Figure 1-17
52
TCU menu: New TCU
Operator panel front: OP 012
Manual, 09/2016, A5E36371591B

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ht 8Sinumerik 840de sl

Table of Contents