9.6 Detector Alarm History
Connect to the detector and navigate to the 'Alarms' tab on
the reading screen by swiping left on the screen.
Browse through the alarm history of the detector.
Select an alarm record. You can see the graphical
representation of the alarm readings.
Tap on the 'EXPORT DATA' button to create a file on the
mobile device containing this data.
The exported data should be interpreted as follows:
SampleCount
StartTime
AlarmTime
EndTime
TimeDelay
AlarmSetPoint
BandThresholds
CounterThreshold
AlgorithmMode
BandEvalStart
BandEvalCount
StddevThreshold
PN 2331M1220 Issue 1
Total number of samples
Timestamp of least recent sample in buffer
Timestamp of alarm event
Timestamp of most recent sample in buffer
Alarm delay in seconds
User configured set point in dB SPL
Level threshold for each frequency band in dB SPL
Evaluation counter threshold
Algorithm mode selected at time of alarm event
First band to consider for evaluation
Number of bands to consider for evaluation
Standard deviation threshold for each frequency band in dB SPL