Pole Mount Installation - Honeywell SEARCHZONE SONIK SZSK-SMG Series Technical Manual

Table of Contents

Advertisement

5.5 Pole Mount Installation
For pole installation, use the optional Pole Mount Fixing Kit. Refer to the Ordering Information section of this manual.
1. For poles 50 to 101 mm (2 to 4 inches) in diameter use the supplied Standard Adjustable Mounting Bracket.
2. For larger poles 101 to 152 mm (4 to 6 inches) in diameter use the Large Adjustable Mounting Bracket (optional; Refer to
section 14 Ordering Information of this manual.)
3. Attach the assembled Standard Adjustable Mounting Bracket (or Large Adjustable Mounting Bracket) to the pole. Align the bracket
flange V-groove with the pole for a good fit. Fix the bracket with two U-bolts and four nuts with washers. Alternatively, fix the bracket
using the Worm Drive Clips. Refer to the figure below.
4. Unscrew both horizontal M10 bolts by 2-3 turns.
5. Adjust the pivot in horizontal position.
6. IMPORTANT: First, tighten the left-facing horizontal M10 bolt (refer to the figure below) to fix the pivot in horizontal position
(torque 30 Nm/22 lb-ft).
7. IMPORTANT: Second, tighten the right-facing horizontal M10 bolt (refer to the figure below) to fix the pivot in horizontal position
(torque 30 Nm/22 lb-ft).
CAUTION
Use of the Worm Drive Clips is NOT recommended for installation on moving objects, e.g., gas carriers.
NOTE
All Mounting Bracket bolts are captive to ensure that they are not accidentally dropped during installation.
Left-facing
horizontal
M10 bolt
Figure 11. Standard Adjustable Mounting Bracket fitment to pole with U-bolts
PN 2331M1220 Issue 1
V-GROOVE
DETAIL
Right-facing
horizontal
M10 bolt
Searchzone Sonik − Technical Manual
5 Mechanical Installation
11/2018
22

Advertisement

Table of Contents
loading

This manual is also suitable for:

Searchzone sonik szsk-sng series

Table of Contents