PLATINUM
S eries
M eters
U ser's
G uide
6.1.4
Process
I nput
T ype
C onfiguration
( INIt
>
I NPt
>
P RoC)
Select
P rocess
( PRoC)
a s
t he
i nput
t ype.
T hen
s elect
t he
p rocess
i nput
r ange
a nd
s cale
i t.
I f
you
s top
a fter
s electing
t he
P RoC
i nput
t ype,
t he
l ast
s elected
i nput
r ange
a nd
s caling
i s
u sed.
Navigate
t o
t he
v oltage
o r
c urrent
r ange
o f
t he
p rocess
i nput.
A ny
s ignal
i nput
o utside
o f
t he
specified
h ardware
i nput
r ange
w ill
r esult
i n
a n
" out-‐of-‐range"
e rror
( code
E 009).
I nput
r ange
choices
i nclude
t he
f ollowing:
4
20
–
4
m A
t o
2 0
m A
( factory
d efault)
•
–
0
24
–
0
m A
t o
2 4
m A
•
–
+
10
–
-‐10
V
t o
+ 10
V
–
•
+
1
–
-‐1
V
t o
+ 1
V
–
•
+
0.1
–
-‐100
m V
t o
+ 100
m V
–
•
+
.05
–
-‐50
m V
t o
+ 50
m V
–
•
Select
t he
d esired
r ange.
The
( tYPE)
o ption
i s
o nly
d isplayed
f or
+ /-‐
1 .0,
+ -‐0.1
a nd
+ -‐
. 05
i nputs
a nd
a llows
s electing
between
S ingle
E nded,
D ifferential
a nd
R atiometric
i nputs.
SING
–
Bipolar
S ingle
E nded
v oltage
b etween
A +
a nd
A RTN
c onnections
•
DIFF
–
Differential
v oltage
b etween
A +
a nd
A -‐
c onnections
•
RTIo
–
R atiometric
r eading
b etween
A +
a nd
A -‐
c onnections.
•
Select
t he
d esired
t ype.
Choose
e ither
m anual
o r
l ive
s caling.
T he
s caling
f unctions
t ranslate
p rocess
v alues
t o
engineering
u nits
a nd
a re
a vailable
f or
a ll
p rocess
i nput
r anges.
T he
d efaults
f or
e ach
i nput
range
a re
t he
h ardware
m inimum
a nd
m aximum.
S caling
m ethods
i nclude
t he
f ollowing:
MANL
–
User
m anually
e nters
a ll
f our
s caling
p arameters
•
LIVE
–
User
m anually
e nters
t he
l ow
a nd
h igh
d isplay
v alues
( RD.1
a nd
R D.2)
b ut
•
reads
t he
i nput
s ignal
d irectly
t o
s et
t he
l ow
a nd
h igh
i nput
v alues
( IN.1
a nd
I N.2)
Scaled
v alues
a re
c alculated
a s:
Scaled
V alue
=
I nput
*
G ain
+
O ffset,
w here:
Gain
=
( Rd.2
–
R d.1)
/
( IN.2
–
I N.1)
Offset
=
R d.1
–
( Gain
*
I N.1)
Therefore
s caling
c an
b e
d one
o ver
a
s ubset
o f
t he
a pplicable
r ange
a s
t his
s caling
c alculation
linearly
e xtrapolates
i n
b oth
d irections.
Select
t he
s caling
m ethod
t o
b e
u sed.
Navigate
t o
t he
d esired
s caling
p arameter.
O ptions
i nclude
t he
f ollowing:
Rd.1
–
Reading
l ow
v alue
c orresponding
t o
I N.1
s ignal
•
IN.1
–
Input
s ignal
c orresponding
t o
R D.1
•
Rd.2
–
Reading
h igh
v alue
c orresponding
t o
I N.2
s ignal
•
IN.2
–
Input
s ignal
c orresponding
t o
R D.2
•
In
M anual
M ode,
I N.1
a nd
I N.2
a re
e ntered
m anually
f or
s caling;,
i n
L ive
M ode,
I N.1
a nd
I N.2
activate
a
r ead
o f
t he
i nput
s ignal
f or
s caling.
Select
t he
s caling
p arameter
t o
c hange.
Reference
S ection:
I nitialization
M ode
( INIt)
24