Address   ( Init   >   C Omm   >   U Sb,   E Thn,   S Er   >   A Ddr); Serial   C Ommunications   P Arameters   ( Init   >   C Omm   >   S Er   > C.par) - Omega PLATINUM Series User Manual

Temperature, process and strain meters
Hide thumbs Also See for PLATINUM Series:
Table of Contents

Advertisement

PLATINUM   S eries   M eters   U ser's   G uide  
 
 
6.6.2
Address   ( INIt   >   C oMM   >   U Sb,   E tHN,   S ER   >   A ddR)  
Select   t he   A ddress   ( AddR)   p arameter.  
 
Set   t he   A ddress   v alue.   T he   M odbus   p rotocol   r equires   a n   a ddress   f ield   t o   c orrectly   i dentify   t he  
 
selected   d evice.   T he   O mega   p rotocol   s upports   a n   o ptional   a ddress   f ield   w hich   i s   r equired   f or  
Serial   c hannels   c onfigured   f or   R S485.    
Accept   t he   e ntered   v alue.  
 
6.6.3
Serial   C ommunications   P arameters   ( INIt   >   C oMM   >   S ER   > C.PAR)  
Select   C .PAR.   T hen,   s elect   i ndividual   p arameters   t o   c onfigure   t he   s erial   c ommunications.  
 
Navigate   t o   t he   c orrect   s etting.   S ettings   i nclude   t he   f ollowing:  
 
bUS.F   –   Specify   R S232   o r   R S485   s erial   c ommunications  
bAUd   –   Baud   r ate   ( transmission   r ate)  
PRty   –   Parity   ( used   f or   t ransmission   e rror   c hecking)  
dAtA   –   Number   o f   b its   p er   d ata   p oint  
StoP   –   Number   o f   s top   b its   b etween   d ata   p oints  
Select   t he   d esired   s etting.  
 
Select   t he   B us   F ormat   ( bUS.F)   p arameter.  
 
Navigate   t o   t he   d esired   s etting.   S ettings   i nclude   t he   f ollowing:  
 
Select   t he   i ndicated   o ption.  
 
Select   t he   B aud   R ate   ( bAUd)   p arameter.   T he   d evice   b eing   c ommunicated   t o  
 
determines   h ow   f ast   y ou   c an   s et   t he   B aud   R ate.  
Navigate   t o   t he   d esired   s etting   f or   B aud   r ate   ( bits   p er   s econd):  
 
Select   t he   i ndicated   o ption.  
 
 
 
 
6.6.3.1 Serial   B us   F ormat   ( INIt   >   C oMM   >   S ER   >   C .PAR  
>   b US.F)  
232C   –   Allows   o ne-­‐to-­‐one   s erial   c ommunications   ( factory   d efault)  
485   –   Allows   m ultiple   d evices   t o   o perate   o n   a   s ingle   p air   o f   w ires    
6.6.3.2 Baud   R ate   ( INIt   >   C oMM   >   S ER   >   C .PAR   >   b AUd)  
19.2   –   19,200   B aud   ( factory   d efault)  
9600   –   9,600   B aud  
4800   –   4,800   B aud  
2400   –   2,400   B aud  
1200   –   1,200   B aud  
57.6   –   57,600   B aud  
115.2   –   115,200   B aud  
 
Reference   S ection:   I nitialization   M ode   ( INIt)  