Download Print this page

Panasonic Aicure UJ20 Series How To Use Manual page 3

Uv curing system
Hide thumbs Also See for Aicure UJ20 Series:

Advertisement

Emergency stop of UV irradiation -2: STOP signal
Use the [STOP] signal terminal [9] to stop the UV irradiation of UJ20.
When the signal is input between terminals [9] and [12], the UV
irradiation will stop, and the [ERROR] signal will be turned on.
[ERROR] is output because the UV irradiation has not completed.
Input [STOP] again or hold down the [SET] key to release
the [ERROR] signal.
START
STOP
UV
ERROR
T
START
STOP
3
Equipment
design
ERROR
COM
Matsushita Electric Works, Ltd.
Global Marketing Division