Download Print this page

Panasonic Aicure UJ20 Series How To Use Manual page 16

Uv curing system
Hide thumbs Also See for Aicure UJ20 Series:

Advertisement

Individual lighting control of multiple heads
[MULTI]-[STATUS]
[MULTI]
Mode to light multiple heads individually with respective external signals
When the [EMISSION] SW is pressed, the heads simultaneously start UV irradiation.
[STATUS]
Mode to continue the UV irradiation while the START signal input stays on.
(Individual heads continue UV irradiation while the respective foot
SWs stay on and stop the irradiation when the SWs are turned off.)
(1) The heads continue UV irradiation for a preset time within the period where the
SWs corresponding to the START1 to 4 signals are kept on.
* When the START signal is turned off, the UV irradiation stops even within the
preset time.
(In this case, the ERROR signal is not turned on.)
(2) The BUSY signals corresponding to the heads are turned on.
* The READY signal is off while all heads 1 to 4 are lit.
* While any of the heads 1 to 4 is ready to start irradiation, the READY signal is on.
(3) When the STOP signal is input, all heads stop the UV irradiation, and the
ERROR signal is turned on.
[MULTI]
[STATUS]
START-1
START-2
START-3
START-4
STOP
START-1
UV-1
BUSY-1
START-2
UV-2
BUSY-2
START-3
UV-3
BUSY-3
START-4
UV-4
READY
BUSY-1
BUSY-2
BUSY-4
BUSY-3
BUSY-4
READY
COM
STOP
ERROR
16
Setting
T1
T2
T3
T4
Matsushita Electric Works, Ltd.
Global Marketing Division

Advertisement