Download Print this page

Panasonic Aicure UJ20 Series How To Use Manual page 11

Uv curing system
Hide thumbs Also See for Aicure UJ20 Series:

Advertisement

UV irradiation while holding SW on and stopping at
the preset time
The UV irradiation continues while the foot SW is stepped on (alternate
input), and stops when the preset time has elapsed.
When the foot SW is turned off, the UV irradiation stops.
[STATUS]: While an external START signal is input, the UV irradiation
continues.
When the START signal is turned off within the preset time, the irradiation
stops.
(1) The UV irradiation starts when the [START] signal is received while the [READY] signal is on.
The UV irradiation starts when the [START] signal is input, and stops when the preset time has
elapsed.
(2) When the UV irradiation stops, the [READY] signal is turned on.
* During UV irradiation, the [READY] signal is off, and the [START] signal input is ignored.
* When the [STOP] signal is input, the UV irradiation stops, and the [ERROR] signal is turned on.
START
STOP
UV-1
BUSY-1
READY
ERROR
T1
START
11
Equipment
design
STATUS
BUSY-1
STOP
Matsushita Electric Works, Ltd.
Global Marketing Division
READY
ERROR
COM