Uv curing system
Hide thumbs Also See for Aicure UJ20 Series:

Advertisement

UV irradiation only by signal inputs regardless of
time setting: [MNL] irradiation
If the mode is switched to manual mode by using the [MNL.] signal, the UV
irradiation can be freely controlled using only external signals regardless of
the UV irradiation time set by UJ20.
(1) Input the [MNL] signal to switch to manual mode. When the mode
is switched, the [READY] signal will be turned off.
(2) While the [START-1/2/3/4 ] signal stays on, the corresponding
CH (head) continues UV irradiation.
(3) When the [MNL] signal is turned off, the mode will be switched to
[AUTO], and the [READY] signal will be turned on.
MNL.
START-1
START-2
START-3
START-4
MNL.
MNL.
READY
START-1
UV-1
BUSY-1
START-2
UV-2
BUSY-2
START-3
READY
UV-3
BUSY-1
BUSY-2
BUSY-3
BUSY-3
BUSY-4
START-4
COM
UV-4
BUSY-4
19