UJ20 inputs/outputs (I/O terminal arrangement)
Pin No.
Signal nam e
Input/Output
1
START   1
2
START   2
3
START   3
START   4
4
5
TYPE   Chg1
6
TYPE   Chg2
TYPE   Chg4
7
8
TYPE   Chg8
9
STOP
10
MNL   ON
11
EMER.
12
COM
13
READY
14
BUSY   1
15
BUSY   2
16
BUSY   3
17
BUSY   4
18
ERROR
19
ALARM
20
COM
21
COM
22
FG
23
+5V
24
GND
Pin Nos. 12, 20, and 21 are internally connected.
The ON time of the input signal pulses must be 100 ms or more.
Des cription
Signal to s tart CH1 or collective irradiation
Signal to s tart CH2 irradiation
Signal to s tart CH3 irradiation
Signal to s tart CH4 irradiation
Signal to s witch irradiation patterns
Signal to s witch irradiation patterns
Signal to s witch irradiation patterns
Signal to s witch irradiation patterns
Signal to activ ate an em ergency stop during irradiation
Signal to switch to m anual m ode (External MN L m ode)
Interlock (norm ally-on)
Com m on term inal for input/output s ignals
Irradiation is ready
ON during CH1 irradiation
ON during CH2 irradiation
ON during CH3 irradiation
ON during CH4 irradiation
Error s ignal
W arning signal (tem perature warning and tim e warning)
Com m on term inal for input/output s ignals
Com m on term inal for input/output s ignals
Fram e ground
5 V DC output (for dis play for output s ignals )
5 V DC ground
Size
AWG#24 - 16
Notes:
(1) Terminal tightening torque: 0.22 N m to 0.25
N m
(2) Carefully strip the cover so as not to damage
the core wires.
(3) Connect the core wires without twisting them.
(4) Connect the core wires without soldering them;
otherwise, they may break due to vibration.
(5) After connection, do not apply stress to the
cable.
(6) Because of the terminal structure, if the wire is
tightened by a counterclockwise rotation, the
connection will fail. In such cases, pull out the
wire, check the terminal hole, and then connect
it again.
25
Equipment
design
MINI COMBICON Plug 12P
(Phoenix Contact MC 1.5/12-ST-
3.5)
Cross section of the
conductor
0.2 - 1.25 mm
2
Matsushita Electric Works, Ltd.
Global Marketing Division