Uv curing system
Hide thumbs Also See for Aicure UJ20 Series:

Advertisement

UV irradiation starting by SW-on and stopping at
a preset time
UV irradiation starts when the foot SW is stepped on (momentary input = no
need for keeping the SW stepped on), and stops when the preset time has
elapsed.
[PULSE]: UV irradiation starts when an external START pulse signal is
input.
When the preset time has elapsed, UV irradiation stops.
(1) The UV irradiation starts when the [START] signal is received while the [READY] signal is on.
The UV irradiation starts when the [START] signal is input, and stops when the preset time has
elapsed.
(2) When the UV irradiation stops, the [READY] signal is turned on.
* During UV irradiation, the [READY] signal is off, and the [START] signal input is ignored.
* When the [STOP] signal is input, the UV irradiation stops, and the [ERROR] signal is turned on.
START
STOP
UV-1
BUSY-1
READY
ERROR
T1
START
10
Equipment
design
PULSE
BUSY-1
STOP
Matsushita Electric Works, Ltd.
Global Marketing Division
READY
ERROR
COM