CLEANING UP AFTER WORK
Q
Reduce pressure to the minimum (turn counter-
clockwise the pressure control knob) (1).
Empty remaining material into bucket until most of
texture material is out of hopper (2).
Fill the tank with clean water (3), or connect a flexible
hose which is connected to the water mains onto the
hose adaptor (3A).
Turn on the pump (4), turn the "Pump Rotation" selector
clockwise, open the tap of the recycle valve, close
the product flow tap and make sure that the water is
recycling completely from the return pipe (5).
At this point, close the recycle valve (6) and open the
product flow tap. Point the spray gun into the receptacle
used to collect the product and hold the trigger down to
expel any remaining product until clean water sprays
out.
WARNING:
Carry out the re-circulation operation
repeatedly until only clean water comes
out of the gun.
In case of long storage, we recommend you to suck
and to leave light mineral oil inside the pumping group
and the flexible hose.
Remove the nozzle from the pistol and was it accura-
tely.
PLEASE NOTE:
In the case of prolonged periods of disuse,
it is best to remove a roller from the rotor
group in the peristaltic pump and leave the
other in a position that does not squash the
hose. This operation serves the purpose of
maintaining the characteristics of the hose
unaltered.
PEGASO
10
12
WATER
4
5
Follow the washing procedure before using
again the equipment.
If water freezes in sprayer, damage may
occur. In cold weather store sprayer here
it will not freeze.
During the washing operations, leave the
air tap slightly open in order to keep the
air channel in the gun clean.