Write cycles at +40 °C
Read/write distance (S
Distance from metal
Multitag capability
Power supply
Degree of protection to EN 60529
Shock according to EN 60721-3-7, Class
7M3
Total shock response spectrum, Type II
Vibration-resistant to EN 60721-3-7, Class
7M3
Torsion and bending load
Enclosure dimensions
Fixing
Tightening torque
Ambient temperature
Weight
1)
2)
3)
4)
5)
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
minimum
typical
)
g
Dimensions (D x H) in mm
Color
Material
2 hours, 2 m, +20 °C
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C
For mounting with the spacer (6GT2690-0AA00), use a stainless steel M5 screw to avoid
damaging the MDS in high temperatures (expansion coefficient).
In higher temperatures (> +80 °C), observe the expansion coefficient of all materials in order to
prevent damage to the MDS due to fastening.
Note that no processing is possible at temperatures of +140 °C or higher.
100 000
1.000.000
See Chapter Field data (Page 35).
min. 30 mm (approx. 30% reduction of the field data)
Yes
Inductive power transmission
(without battery)
IP68
1)
IPx9K
2)
50 g
20 g
Not permissible
85 (±0.5) x 15 (-1.0)
Black
Plastic PPS, silicone-free
3 x M5 screw
1,5 Nm
4)
-25 °C to +100 °C
During
operation
+120 °C to +140 °C
+200 °C
5)
+220 °C
-40 °C to +100 °C
Transport
and storage
Approx. 50 g
1)
Permanent
20% reduction in the limit
distance
Tested up to 5000 hours or
3000 cycles
Tested up to 2000 hours or
1500 cycles
Transponder
7.6 MDS D139
177