Dimension Drawing - Siemens SIMATIC Ident System Manual

Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Power supply
Degree of protection to EN 60529
Shock according to EN 60721-3-7, Class 7M3
Total shock response spectrum, Type II
Vibration-resistant to EN 60721-3-7, Class
7M3
Torsion and bending load
Enclosure
Fixing
Tightening torque at +20 °C
Ambient temperature
Weight, approx.
1)
7.17.5

Dimension drawing

Dimensions in mm
Figure 7-47
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Color
Material
Dimensions (D x H) in mm
During operation
Transport and storage
The values for shock and vibration are maximum values and must not be applied continuously.
Dimension drawing of MDS D424
Inductive power transmission
(without battery)
IP67
100 g
1)
20 g
1)
Not permissible
Black
Epoxy casting resin
27(±0.2) x 4(±0.2)
M3 screw, adhesive
≤ 1 Nm
-25 °C to +85 °C
-40 °C to +100 °C
5 g
Transponder
7.17 MDS D424
223