Pin Assignment Of Dc Outputs And Mains Connection - Siemens SIMATIC Ident System Manual

Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Accessories
8.3 Wide-range power supply unit for SIMATIC RF systems
Technical specifications - standards complied with
Designation
Electrical safety
Conducted interference
Emission
All values are measured at full-load and at an ambient temperature of +25 ℃ (unless
specified otherwise).
8.3.7

Pin assignment of DC outputs and mains connection

DC outputs
Mains connection
254
Standard
EN 60950 / UL 60950 / CAN/CSA 22.2 950, 3 Edition
EN 61000-6-3
EN 55011
EN 61000-6-3
EN 55011
Assignment
(1) Ground (0V)
(2) +24 V DC
(3) +24 V DC
(4) Ground (0V)
Assignment
(1) 100 to 240 V AC
(2) n.c.
(3) 100 to 240 V AC
(4) n.c.
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Values
Class B
Class B