7.3.4
Technical specifications
Table 7- 7
Memory size
Memory configuration
•
•
•
Storage technology
Memory organization
Data retention (at +40 °C)
MTBF (at +40 °C)
Read cycles
Write cycles (at +40 °C)
•
•
Read/write distance (S
Distance from metal
Multitag capability
Maximum reader power
in hazardous area
Maximum field strength
for operation in hazardous area
Power supply
Degree of protection to EN 60529
Shock according to EN 60721-3-7, Class 7M3
Total shock response spectrum, Type II
Vibration-resistant to EN 60721-3-7, Class
7M3
Torsion and bending load
Enclosure
•
•
•
Fixing
Tightening torque
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
Technical data for MDS D124
Serial number
Configuration memory
Application memory
minimum
Typical
)
g
Dimensions (D x H)
Color
Material
128 bytes
8 bytes (fixed code)
•
8 bytes
•
112 bytes
•
EEPROM
Refer to the MOBY D system manual, RF200 or
RF300
section "Memory configuration of the ISO tags"
10 years
≥ 2 x 10
hours
6
Unlimited
100 000
•
1 000 000
•
See section "Field data (Page 35)."
at least 15 mm (approx. 30% reduction of the field
data)
Yes
2 W
5 A / m
Inductive power transmission
(without battery)
IP68
1)
IPx9K
2)
100 g
3)
20 g
3)
Not permissible
27 x 4 mm (±0.2 mm)
•
Black
•
Plastic PPS, silicone-free
•
Adhesive, M3 screw, snap-in (spacer)
≤ 1 Nm
Transponder
7.3 MDS D124
165