Technical Specifications - Siemens SIMATIC Ident System Manual

Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Flush-mounted in metal
It is possible to mount the MDS D423 in metal.
a
Figure 7-43
7.16.4

Technical specifications

Table 7- 32
Technical specifications of MDS D423
Memory size
Memory configuration
Serial number
Configuration memory
Application memory
Storage technology
Memory organization
Report
Data retention (at +40 °C)
MTBF (at +40 °C)
Read cycles
Write cycles (at +40 °C)
Read/write distance (S
)
g
Mounting on metal
Mounting in metal
Power supply
SIMATIC RF200
System Manual, 09/2013, J31069-D0227-U001-A8-7618
≥ 10 mm
Flush-mounting of MDS D423 in metal
2048 bytes
8 bytes (fixed code)
40 bytes
2000 bytes
FRAM
FRAM, 2048 bytes gross
2000 bytes net
(when using the OPT area, 16 bytes of it must be subtracted in 8
byte blocks)
ISO 15693
10 years
2 x 10
hours
6
Unlimited
> 10
10
See section "Field data (Page 35)."
Yes
yes, with 10 mm clearance all round
inductive power transmission (without battery)
Transponder
7.16 MDS D423