Transponder
7.17 MDS D424
Flush-mounting
h
a
Figure 7-46
Note
If the minimum guide values (h) are not observed, a reduction of the field data results. It is
possible to mount the MDS with metal screws (M3 countersunk head screws). This has no
tangible impact on the range.
7.17.4
Technical specifications
Table 7- 34
Memory size
Memory configuration
•
•
•
Storage technology
Memory organization
Protocol
Data retention (at +40 °C)
MTBF (at +40 °C)
Read cycles
Write cycles (at +40 °C)
Read/write distance (S
Distance from metal
Multitag capability
222
≥ 25 mm
≥ 25 mm
Flush-mounting of MDS D424 in metal with spacer
Technical data of MDS D424
Serial number
Configuration memory
Application memory
)
g
2048 bytes
8 bytes (fixed code)
•
40 bytes
•
2000 bytes
•
FRAM
2048 bytes gross
2000 bytes net
ISO 15693
10 years
≥ 1.5 x 10
hours
6
Unlimited
> 10
10
See Chapter Field data (Page 35)
Min. 25 mm (ca. 30% reduction of the field data)
Yes
System Manual, 09/2013, J31069-D0227-U001-A8-7618