Figure 6
Screwing in the probe
4 Once all the parts are in place, use two wrenches (one holding the head bolt and the other, the probe
slot) to apply the recommended torque (see below) in both directions at the same time.
Figure 7
Tightening the probe
NOTICE
There are two sizes of head locks: 8.9 mm (0.35 in) and 13.5 mm (0.53 in). The
recommended torque, as specified by the manufacturer is as follows:
• 2.8 N·m (2.1 lbf.ft) for the 8.9 mm lock.
• 13.5 N·m (10.0 lbf.ft) for the 13.5 mm lock.
For more information on the reference parameters used to determine the specified
torque, refer to the manufacturer's (Nord-Lock) website.