HP J3188A Installation And Reference Manual page 14

Table of Contents

Advertisement

Installing the Hub
Installing and Configuring Your Hub
2.
1-4
Check the LEDs on the hub's front panel. When the hub is powered on, it
performs a power-on self test. See the table below for the LED pattern
that occurs during the self test.
On for 20 seconds,
On for five
then enters
seconds, then
normal operating
enters normal
state.
operating
state.
LED
Pattern
Port LEDs,
ON for approximately 20 seconds, then enters normal operating
Fault, Security,
state.
AUI
Activity,
ON for approximately five seconds, then enters normal operating
Collision, RPS
state.
System
Stays ON.
Note that once you have connected cables to the hub, a Port LED stays
on if link beat has been detected at the port. A Port LED turns off if link
beat is not detected. The AUI port stays on if it is enabled.
When the self test completes successfully, the LEDs go into their normal
operational states. If a hub hardware fault exists, the hub will not
complete self test. This will be indicated by an abnormal LED pattern.
If the self test time elapses and the Fault LED continues to stay on instead
of turning off, the hub may have an error condition. If repeating the self
test does not correct the problem and the Fault LED still stays continu-
ously on, contact your reseller for replacement information. After the hub
has passed its self test, you are ready to mount the hub.