Operation/Alarm Messages - Sony PDW-700 Operation Manual

Professional disc camcorder
Hide thumbs Also See for PDW-700:
Table of Contents

Advertisement

Warning
State
indication
Problem
Internal temperature high.
Warning
State
indication
Problem
Internal drive sensor error
a) Asterisks (*) are replaced by digits in the display.
b) During recording
c) During playback, fast forward, fast reverse, or stop
d) During recording pause
e) During recording or pause
f) 1 flash/s
g) 4 flashes/s
h) During recording, displayed in the LCD monitor only
(when the DISP SEL switch is set to STATUS)
For details about the warning displays and alarm
messages on the viewfinder, see the next item.

Operation/alarm messages

An operation or alarm message is displayed in the
operation/alarm message display area (see page
32) of the viewfinder screen.
LOW
Depending on the setting, the
LIGHT
subject illumination is inadequate.
ON-BOARD
The backup battery of the internal
BATTERY
clock is empty.
EMPTY
DCP
If this message continues to appear
EEPROM
even after the unit is powered off
DATA NG!
and on again several times, then
DR
the factory adjustment data is
EEPROM
invalid. Contact a Sony service
DATA NG!
representative.
DCP/DR
EEPROM
DATA NG!
a) Contact a Sony service representative to exchange the
battery.
WARNING
indicator
VDR operation
Operation continues.
WARNING
indicator
VDR operation
Operation continues.
a)
Warning sound
REC/TALLY
Action to take
Power the unit off and move it
to a cool place.
Warning sound
REC/TALLY
Action to take
Protect the unit from shocks
and vibrations, turn off the
power, and contact a Sony
service representative.
A message for VDR operation is displayed in the
setting change and adjustment progress message
display area of the viewfinder screen (see page
32). Take the necessary action indicated in the
following table.
ILL. Disc!
A disc that cannot be used by this
unit was inserted. Insert another
Professional Disc.
ILL. Index!
Index file or file system error.
No FS!
Exchange or format the disc.
Unknown FS!
No Support!
A recorded clip cannot be handled
by this unit. Exchange or format
the disc.
FORMAT
The disc could not be formatted
NG!
automatically. Exchange the disc.
Disc Damage
A disc that cannot be recorded was
inserted. To record, exchange the
disc.
Non AV Full
The disc is full. Exchange or
MAX # Files
format the disc.
Over DUR!
DI read err
The disc was not recognized. Try
Read err
ejecting the disc and inserting it
DRV ADJ err
again. Or exchange the disc.
Run Salvage
A disc that requires salvage was
inserted. To record on the disc,
eject the disc, insert it again, and
execute salvage processing.
BATT