Performance data

2.5 PROFINET IO characteristic data

Characteristic
Execution times of the FCs AG_SEND / AG_RECV
The execution time required to process the FC blocks (AG_SEND, AG_RECV) required on
the S7-300 / C7-300 CPU is decisive for the calculation of the CPU cycle times (OB1) for
SEND/RECEIVE connections.
Note
Measurements of transmission and reaction times in Ethernet, PROFIBUS and PROFINET
networks for a series of configurations can be found on the Internet at the following address:
25209605 (http://support.automation.siemens.com/WW/view/en/25209605)
2.5
PROFINET IO characteristic data
Possible modes with PROFINET IO
In PROFINET IO, the CP can operate as a PROFINET IO device or as a PROFINET IO
controller.
Configuration limits of the CP as a PROFINET IO controller
The CP supports the following maximum configuration as a PROFINET IO controller:
Table 2- 5
Configuration limits of the CP as a PROFINET IO controller
Characteristic
Number of operable PROFINET IO devices
Size of the input area over all PROFINET IO devices ***)
Size of the output area over all PROFINET IO devices
Size of the IO data area per submodule of a module in an IO
device
20
Transfer is not confirmed
No receipt of UDP broadcast
UDP frame buffering
Explanation / values
The transfer of UDP frames is unconfirmed, in
other words the loss of messages is not detected
or displayed by the send block (AG_SEND).
To avoid communications overload of the CP due
to high broadcast load, the CP does not allow
receipt of UDP broadcasts.
Size of the frame buffer with buffering enabled: 2
Kbytes
Note:
Following a buffer overflow, newly arriving frames
are discarded.
Explanation / values
32 *), **)
1024 bytes max.
1024 bytes max.