Mounting
4.3

Cables

All cables must be professionally installed. Bending radii (see data sheets of manufacturer) must
be adhered. The cables must be protected from chafing and buckling by suitable installation.
Damaged cables must not be used and need to be replaced immediately.
If the recommended cables cannot be used (e.g. due to missing UL/CSA approval), substitutes
should be cleared with Roland Electronic.
4.3.1

Sensor cables

The sensors are available either with plug connector or with fixed cable. For connecting, only the
supplied shielded sensor cables may be used. In the standard version those cables are suitable for
drag-chain operation but not for robot operation.
The cable shield is connected at both sides.
4.3.2

Power supply / Control cables

Suitable power supply / control cables:
- Type H05VV5-F (Lapp Ölflex® 140) with leads 0.5 mm²
- Type H05VVC4V5-K (Lapp Ölflex® 140CY), shielded, with leads 0.5 mm².
A shielded cable must be used if the environment has high electromagnetical interference signals.
This cable shield must be grounded at the machine side, not at the control unit side.
Pos: 21 /Kapitelübersicht/05. Elektrische Installation @ 0\mod_1121421905234_501.doc @ 509 @
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
22
Double Sheet Detector R100 I100
Keep the sensor cables as well as the power supply / control cable
Note!
away from unshielded cables with strong electro magnetical
interference potential (e.g. servo motor and power cables).
Manual
for pairs of sensors
B0003308 / 1.4 / 13.02.2013