Electrical installation
5.3

Connections at I100-S

Fig. 13: Connections I100-S
Supply socket (pos. 1)
view onto contacts
The associated cable plug (contacts) is not within the scope of delivery, it must be ordered separately under S0003515.
See also chapter "Order data".
Sensor socket f. receiver (pos. 2)
3
view onto contacts
Sensor socket f. transmitter (pos. 3)
3
2
view onto contacts
Fig. 14: sockets I100-S
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
26
Double Sheet Detector R100 I100
1
2
Socket at unit
Enclosure HAN 3A, EMI-type, metrical
7-pin insert with PE, Pin contacts at control unit
Pin1
+24V DC
Pin 2
common / GND
Pin 3
Teach-In
Pin 4
2-sheet
Pin 5
1-sheet
Pin 6
0-sheet
Pin 7
+24V DC f. I/O
Pin 8
Socket at unit
M12, 2-pin, B-coded,
female connector at control unit
1
Pin 1
Pin 2
Enclosure
Shield
Socket at unit
M12, 3-pin, B-coded,
female connector at control unit
Pin 1
+12V
1
Pin 2
Pin 3
common / GND
Shield
Manual
for pairs of sensors
3
Internal Pin 2
Internal Pin 3
Internal Pin 4
Internal Pin 5
Internal Pin 6
Internal Pin 7
Internal Pin 8
PE
Internal Pin 1
Internal Pin 10
+V
in
Internal Pin 11
-V
in
Internal Pin 14
Internal Pin 15
-12V
Internal Pin 17
Internal Pin 16
Internal Pin 18
B0003308 / 1.4 / 13.02.2013
1
Supply socket
2
Sensor socket f. receiver
3
Sensor socket f.
transmitter
Supplier / types / remarks
Harting and others
Supplier / types / remarks
Binder Type 713 and others
Wire colour: brown
Wire colour: white
transparent / green-yellow
Supplier / types / remarks
Binder Type 713 and others
Wire colour: brown
Wire colour: white
Wire colour: green
transparent / green-yellow