PROGRAMMING
FAHRENHEIT OR CELSIUS
The temperatures displayed can be set to Fahrenheit or Celsius scale by holding up button to
change into Fahrenheit and holding down button to change into Celsius. All digits displayed will be
automatically converted to the designated scale.
DISPLAY BRIGHTNESS
To adjust the brightness of the display, please be in the main screen view, then press the up button
repeatedly to increase the brightness. Press the down button repeatedly to decrease the bright-
ness. There are three brightness settings available.
CONTROLLER LOCK
Holding the LEAF button for three or more seconds will lock the controller. The controller will still
work as programmed; however, pressing any buttons will not have an effect and will cause the
screen lock icon to flash and will make an audible beep three times a second. This option was
designed to prevent your controller settings from being changed by accident. Holding the LEAF
button again for three or more seconds will unlock the controller.
BUFFER
Holding the MODE button and up or down button simultaneously, you can change the buffer to 2
or 4. For high temperature or alarm triggers, the fans will stop running when the measured value
falls below your set value by the number set as the buffer. For low temperature or alarm triggers,
the fans will stop running when the measured value rises above your set value by the number set
as the buffer.
ECO-DISPLAY
To conserve energy, you can choose to set the display into Eco Mode by pressing the button with a
leaf on it to turn the display off. All programs will be operating in the background and fans will still
be triggered to run according to the settings. Press any button will turn the display back on.