Blocked Vent Switch - PSG CADDY Series Installation Manual

Optional oil unit

Advertisement

Technical data – Oil unit
BURNER
BTU
MODEL
TYPE
INPUT
UH–
BECKETT
90,000
CADDY
AFG
UH–
RIELLO 40
91,000
CADDY
F3

BLOCKED VENT SWITCH

A Blocked Vent Switch is mandatory for installation with an oil-fired
appliance that normally operates with its vent system under a negative
pressure. This device is intended to detect a blocked vent system,
responds to hot flue gases backing up through its heat transfer tube,
and can be wired to shut off the oil burner. It requires manual resetting.
18
NOZZLE
FLOW
0.55 X 60
W
0.55 GAL US/H
0
(DELAVAN)
(2.08 L/H)
0.50 X 70
W
0.60 GAL US/H
0
(DELAVAN)
(2.27 L/H)
STATIC
PRESSURE
HEAD
PLATE
AT THE PUMP
140 PSI
L2
YES
(965 kPa)
150 PSI
---
---
(1035 kPa)
H.P. FAN
TUBULATOR
MOTOR
ADJUSTMENT
ADJUSTMENT
1/3
---
1/3
1
AIR
EFFICIENCY
0/2
85%
2.5
87%