PRODUCT DESCRIPTION AND USER'S MANUAL

5 MBF-40 Commissioning

After the repeater is connected, it is identified by the OMU II via the Fiber connection
and the unit is commissioned from the OMU II. The commissioning process consists of a
few simple steps.
MBF-40 Setup and Commissioning consists of the following
1. Opening an OMU II session – for accessing the MBF-40 configuration window (via
OMU II)
2. Performing Optical Loss Adjustment on the connected MBF-40
3. Setting the required RF attenuation and gain levels on the remote MBF-40
4. Assigning the unit a recognizable name (according to its location)

5.1 MBF-40 Optical Loss Adjustment (OLA)

MBF-40 OLA is performed from the OMU II.
For MBF-40 remotes, the maximum compensation is increased to 26dB to support
shorter Fiber optic distances.
To perform MBF-40 OLA (via OMU II)
1. From the OMU II main window, click the Opto Adjust button.
56
Figure 5-1: OMU II Main window