3.4.1 Required Items for a Master Slave System
In addition to the items provided in the Master/Slave Repeater package, you will require
the following cables for interconnecting the Master Slave units:
2 high power 50ohm coaxial (jumper) cables with N male connectors on both side
•
1 low loss, high quality 50ohm jumper cable with 7/16 male connectors on both side
•
1 standard straight CAT5 (or above) Ethernet cable with RJ45 connectors on both
•
side
NOTE: The length of the cables depend on the distance that the Master and Slave units are mounted
from each other.
3.4.2 Mounting the Master and Slave Units
The Master and Slave units are mounted near each other on the wall.
ATTENTION!!! Recommended distance between the units depends on RF jumper cables used and
their loss. Maximum distance for low less cables ~5m
To mount the Master and Slave Units
1. Mark the intended location of the Master and Slave units on your wall.
2. Mount the Master as follows:
• For Master units provided WITH a Fan Hood assembly kit, mount according
to section 3.3.
• For Master units WITHOUT a Fan Hood assembly kit, mount according to
section 3.2.
3. Mount the Slave unit according to section 3.2.